INSTALLATION MANUAL 

PrimeFire#4 

 PrimeFire#4 REMOTE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Manufactured by:

 

 

Planika Sp. z o.o. 

ul. Bydgoska 38 

86-061 Brzoza 

Poland 

 

[mm] 

[‘’] 

139 

1

/

2

 

H1 

137 

3

/

8

 

H2 

1

/

16

 

700 

27 

9

/

16

 

L1 

500 

19 

11

/

16

 

L2 

100 

15

/

16

 

245 

5

/

8

 

Fixed unit’s weight 

= 15 kg / 33,07 lb 

Automatic fuel pump 

 

SERVICE KIT 

* only REMOTE 

Summary of Contents for PrimeFire 4

Page 1: ...ROR PAT P EN D ECO Planika I N T E L L I G EN T F I R E INSTALLATION MANUAL PrimeFire 4 PrimeFire 4 REMOTE Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland mm H 139 5 1 2 H1 137 5 3 8 H2 2 1 16 L 700 27 9 16 L1 500 19 11 16 L2 100 3 15 16 D 245 9 5 8 Fixed unit s weight 15 kg 33 07 lb Automatic fuel pump SERVICE KIT only REMOTE ...

Page 2: ...ndustrial dusts etc No flammable items should be placed in direct contact and within a radius of 1 m 3 28 ft around the device Do not place near curtains net curtains etc Do not expose the device to weather conditions The product is for internal use only Do not expose the device to meteorological conditions The device is for indoor use only Do not place the device in close proximity to sources of ...

Page 3: ...e it must be made of non flammable materials and the minimum distance from the furnace must be kept not less than 35 cm 13 in It is not allowed to use a device before placing it into a prepared wall recess or other housing cavity min 1000 mm min 39 3 8 min 1500 mm min 59 1 16 min 1000 mm min 39 3 8 min 1000 mm min 39 3 8 min 50 mm min 1 15 16 min 50 mm min 1 15 16 Due to fire safety it is forbidde...

Page 4: ...e going to set the furnace inset is well levelled as later it will not be possible to level the insert min 150 mm min 5 7 8 700 mm 27 9 16 680 mm 26 3 4 2 mm 1 16 min 710 mm min 27 15 16 230 mm 9 1 16 680 mm 26 3 4 230 mm 9 1 16 min 150 mm min 5 7 8 680 mm 26 3 4 min 255 mm min 10 1 16 min 12 mm min 1 2 min 13 mm min 1 2 min 350 mm min 13 3 4 B A A A min 710 mm min 27 15 16 B B min 13 mm min 1 2 m...

Page 5: ... it can cause leaks of the Fanola liquid and the danger of fire Then connect the supplied cable with a connection block at the end of the cord Note that connection to the mains must be made by a qualified electrician The furnace assembly A is connected to mains now Set it in the prepared cavity Level the surface of the cavity The deviation cannot exceed 2 mm 1 16 in Connection to the mains must be...

Page 6: ...You are not allowed to fill the fuel tank and start the device before having read the instruction manual If in the future it is necessary to take the device out of the housing wait until the fuel has burned up completely and the display shows disconnect the power supply and take the device out of the housing Keep this instruction manual throughout the lifetime of the device FUEL ...