5
REFUELLING
1.
Open the control panel (I). If the tank is empty (
) or you want to fill the fuel, open the fuel inlet (II),
firmly connect the pump hose ‘a’ (click!) and power cable ‘b’ (III) (
).
ATTENTION!
Do not refuel
when the flame is ignited!
2.
Place the fuel container stably on the floor and insert the pump hose ‘c’ (IV). Press and hold the button
on the pump to start refuelling (V).
Once the fuel container has been emptied, replace it with a full one and start the pump again (see point 2).
The pump will stop when the tank is full (sound +
).
3.
Disconnect the power cable ‘b’. To disconnect the pump, hold the end of the hose ‘a’ and firmly press the plate in the
place marked with a sticker (VI). Close the fuel inlet.
4.
Shake the remaining fuel from the hose ‘c’ to the container and place the pump in the bag (VII).
FLAME IGNITION
The green diode
indicates that the device is ready to ignite the flame.
Press and hold
START
for 3 seconds. Flame ignition will take 2-10 minutes (
). The smell of ethanol vapours can be
present during the ignition. The diode
READY
off (
) indicates that
the flame has been ignited and the device
reached the working temperature.
I
II
III
a
b
IV
c
F
U
E
L
V
VI
a
b
VII
c
E
N
G
L
IS
H