Copyright Planika Sp. z o.o.
www.planikafires.com
IG0251#05
06.03.2019
52
VERSAL Insert 550
VERSAL Insert 700
Type
Version
Combustion
Supply and discharge system
Flame protection version
Protection against backward chimney draft
Type of the device
Weight of the device
I2E(20), I2H(20) I2L(25), I2EK(25)
I2E+(20/25)
I3P(30)
I3P(37)
I3P(50)
I3B/P(30)
I3B/P(37)
I3B/P(50)
I3+(30/37)
G20
G25/G25.3
G20/G25
G31
G30
G30/G31
Nominal heat input (Hi)
kW
Consumption on max output
m3/h
Consumption on low output
m3/h
Consumption on max output
kg/h
Consumption on low output
kg/h
Maximum burner pressure
mbar
9,7
13,4
18,7/23,7
24,0
24,0
29,0/36,0
Minimum burner pressure
mbar
4,0
5,6
5,7
6,3
6,6
6,6
Nozzle of the main burner
mm
1x Ø 2,0
1x Ø 2,0
1x Ø 1,75
1x Ø 1,3
1x Ø 1,2
1x Ø 1,15
Primary air opening
mm
2x 0,5
2x 0,5
2x 0,5
2x 4
2x 4
2x 3
-
0,39
-
0,13
4,59
4,94
0,49
-
0,16
-
Reference Gas
TECHNICAL SPECIFICATIONS
Model
VERSAL Insert 550 F, VERSAL Insert 550 LF, VERSAL Insert 550 FR
VERSAL Insert 550 LFR, VERSAL Insert 550 W, VERSAL Insert 550 T, VERSAL Insert 550 RD
To be built-in
Open combustion chamber
Conventional Flue 200 mm
Separate ignition and ionization electrodes
Yes / Thermal sensor/ Pressure sensor
B
BS
Appliance category
VEGA/400/F/H, VEGA/400/LF/H, VEGA/400/FR/H, VEGA/400/LFR/H, VEGA/400/W/H, VEGA/400/T/H, VEGA/400/RD/H
22 kg
Type
Version
Combustion
Supply and discharge system
Flame protection version
Protection against backward chimney draft
Type of the device
Weight of the device
I2E(20), I2H(20) I2L(25), I2EK(25)
I2E+(20/25)
I3P(30)
I3P(37)
I3P(50)
I3B/P(30)
I3B/P(37)
I3B/P(50)
I3+(30/37)
G20
G25/G25.3
G20/G25
G31
G30
G30/G31
Nominal heat input (Hi)
kW
Consumption on max output
m3/h
Consumption on low output
m3/h
Consumption on max output
kg/h
Consumption on low output
kg/h
Maximum burner pressure
mbar
9,7
13,4
18,7/23,7
24,0
24,0
29,0/36,0
Minimum burner pressure
mbar
4,0
5,6
5,7
6,3
6,6
6,6
Nozzle of the main burner
mm
1x Ø 2,2
1x Ø 2,2
1x Ø 1,9
1x Ø 1,4
1x Ø 1,3
1x Ø 1,25
Primary air opening
mm
2x 0,5
2x 0,5
2x 0,5
2x 4
2x 4
2x 3
-
0,47
-
0,16
5,25
5,96
0,56
-
0,19
-
Reference Gas
TECHNICAL SPECIFICATIONS
Model
VERSAL Insert 700 F, VERSAL Insert 700 LF, VERSAL Insert 700 FR
VERSAL Insert 700 LFR, VERSAL Insert 700 W, VERSAL Insert 700 T, VERSAL Insert 700 RD
To be built-in
Open combustion chamber
Conventional Flue 200 mm
Separate ignition and ionization electrodes
Yes / Thermal sensor/ Pressure sensor
B
BS
Appliance category
VEGA/500/F/H, VEGA/500/LF/H, VEGA/500/FR/H, VEGA/500/LFR/H, VEGA/500/W/H, VEGA/500/T/H, VEGA/500/RD/H
26 kg