Copyright Planika Sp. z o.o.
www.planikafires.com
IG0251#05
06.03.2019
44
7.5.
Checklist
Range
Actions
1 General inspection
•
Carry out the procedure in firing up the fireplace
•
Check the operation of all safety systems.
•
Check if the flame of the main burner burns steadily
•
Check if the main burner is burning evenly
•
Check the correct operation of all modes of the remote control.
2
Glass Control
•
Make sure that the glass has no cracks.
•
Make sure the glass fits tight to the body of the fireplace.
•
Check the wear of the seals. If necessary, replace the seal.
•
Check the degree of contamination of the glass. Clean the glass if necessary.
3
Combustion
chamber control
•
Check whether the ignition electrode is not obstructed by decorative elements
•
Check if the ionization electrode is within the range of the main burner flame
•
Check whether the combustion chamber does not require cleaning.
•
Check if the spaces supplying air from the flue pipe system to the combustion
chamber are not obstructed. If necessary unblock those spaces.
•
Check whether the combustion chamber has no signs of corrosion. If necessary,
remove corrosion and cover the losses with a new coat of fireplace paint.
•
Check if the main burner ignites smoothly.
4
Flue Control
•
Check the tightness of the concentric flue system
•
Check the patency of the concentric flue system.
5
Monitor of the
control devices
•
Make sure the receiver is not damaged.
•
Check if the circuits has no breakthrough
•
Make sure the power supply cable is not damaged
•
Check that the components of the control system are not exposed to overheating.
6
Housing control
•
Make sure the casing of the gas insert has no cracks
•
Check whether the combustible elements are at a safe distance from the casing of the
fireplace.
7
Decorative
elements
•
Check that the decorative elements do not require cleaning
•
Check that the decorative elements are not in contact with the glass
•
Check if the decorative elements are not damaged.