9
Electronic Panel Housing Dimensions
The control panel is normally mounted on the wall of the observatory. The cables connect to the
bottom of the box and should be routed down the wall, under the observatory floor over to the
telescope and back up through the floor
Telescope control Box Input
Input Voltage:
o
90-264V AC for the single phase
o
340-550V AC for the three phase
Input Frequency: 47-63 Hz
Input Current: 0.6 A to 8A
Inrush Current: cold start 60 A max
Power Factor: All units are
EN61000-3-2 compliant
There are three power supplies in the Telescope Control Box. There is a 12V, 24V and two 48V power
supplies. The 12V is to provide power to the telescope for standard 12V accessories and for the EFA kit