IGS-6325-8UP2S/IGS-6325-8UP2S2X:
DC 48~56V
PWR1
PWR2
Fault
DI1 DO0 DO1
DI0
GND
GND
DC Input:
48-56V , 7.5A max.
Max. fault loading: 24V, 1A
Dual power input is required
for maximum PoE loading.
Refer to user’s manual for
more details.
1 2 3 4 5 6
1 2 3 4 5 6
Figure 3-3:
IGS-6325-8UP2S/IGS-6325-8UP2S2X Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1
2
3
4
5
6
V+
V-
V+
V-
Power 1
Power 2
Figure 3-4:
The pin of 6-contact terminal block connector
Note
1. The wire gauge for the terminal block should be in the range
from
12
to
24 AWG
.
2. Please check the wire AWG Ampere specification before