User’s Manual of IGS-5225 series
182
That is, although the VLAN 2 members: Port-1 to Port-3 and VLAN 3 members: Port-4 to Port-6 also belongs to VLAN 1. But
with different PVID settings, packets form VLAN 2 or VLAN 3 is not able to access to the other VLAN.
6. Repeat Steps 1 to 6, set up the VLAN Trunk port at the partner switch and add more VLANs to join
the VLAN trunk, repeat Steps 1 to 3 to assign the Trunk port to the VLANs.
4.3.3.8.3 Port Isolate
The diagram shows how the
Industrial Managed Switch
handles isolated and promiscuous ports, and the each PC is not able
to access the isolated port of each other’s PCs. But they all need to access with the same server/AP/Printer. This section will
show you how to configure the port for the server – that could be accessed by each isolated port.
Setup steps
1. Assign Port Mode
Set Port-1~Port-4 in Isolate port.
Set Port5 and Port-6 in Promiscuous port. The screen in
Figure 4-3-3-15
appears.
Figure 4-3-3-15:
The Configuration of Isolated and Promiscuous Port