background image

12

Reset

This button is used to restore the all factory default settings. 
Sometimes restarting the device will make the system back to 
a normal state. However, if the system still got problems after 
restart, user can restore the factory default settings and install it 
again.
Restore the device: 

1. While the Camera is ready and then press the button down 

continuously.

2. Hold the button at least 5 seconds and release it. Then the 

device has been restored to default settings and reboot again.

Note

Restoring the factory default setting will lose the all 
previous settings included IP address forever. User 
needs to run the IPWizard II program to search the 

device and configure it to let the device work properly 

again.

2.3.3 Installation

1. Fix IR camera to desired location with wall mount fixture.

2. Plug-in Ethernet Cable into RJ-45 connector.

  Connect  an  Ethernet  cable  to  the  LAN  socket  located  on  the  Network  Camera’s 

back panel and attach it to the network.

3. Connect RS485 D+ and D- (if you need to control PT scanner).

4. Connect  the  attached  power  adapters  to  camera  and  heater  (option/by  model) 

and plug-in these adapters into power outlet.

5. Done.

Summary of Contents for ICA-3350V

Page 1: ...3 Mega Pixel Vari Focal IR Fisheye IP Camera ICA 3350V ICA 5350V ICA 8350 Quick Installation Guide ...

Page 2: ... Camera 4 2 1 1 Package Content 4 2 1 2 Physical Details 4 2 1 3 Installation 6 2 2 ICA 5350V 3 Mega Pixel Vandal Proof IR IP Camera 7 2 2 1 Package Content 7 2 2 2 Physical Details 7 2 2 3 Installation 9 2 3 ICA 8350 3 Mega Pixel Vandal Proof Fisheye IP Camera 10 2 3 1 Package Content 10 2 3 2 Physical Details 10 2 3 3 Installation 12 Chapter 3 Camera Windows Utility 13 Further Information 16 ...

Page 3: ...ient to another This state of art design is considerable to fit in various network environments 1 1 Before Installation Before installation please be sure to read this quick installation guide and user s manual CD carefully to complete machine installation This guide shows how to quick set up these cameras unless model name specified terms IP Camera will be used for these three models 1 2 System R...

Page 4: ...50V x 1 Power Adapter x 1 Accessory Kit x 1 User s Manual CD x 1 Quick Installation Guide x 1 Note If any of the above items are missing please contact your dealer immediately 2 1 2 Physical Details ICA 3350V Connector DI DO MIC AUDIO DC RJ 45 RESET VIDEO 12V DI GND DO 485 485 1 2 3 4 5 6 Color Green 8 1 Green LED Orange LED Color Pink ...

Page 5: ...onnect to sensor in and alarm out devices Cable for I O connectors Name Number Function 12VDC 1 DC 12V 50mA maximum DI 2 Digital signal input GND 3 GND DO 4 Digital signal output 485 5 RS485 data 485 6 RS485 data MIC in Audio in Connect a microphone to the network camera Audio out Connect a loud speaker to the network camera This function is for voice alerting and two way audio Video out BNC conne...

Page 6: ... and reboot again Note Restoring the factory default setting will lose the all previous settings included IP address forever User needs to run the IPWizard II program to search the device and configure it to let the device work properly again 2 1 3 Installation 1 Fix IR camera to desired location with wall mount fixture 2 Plug in Ethernet Cable into RJ 45 connector Connect an Ethernet cable to the...

Page 7: ...Accessory Kit x 1 User s Manual CD x 1 Quick Installation Guide x 1 Note If any of the above items are missing please contact your dealer immediately 2 2 2 Physical Details ICA 5350V Connector DI DO MIC AUDIO DC RJ 45 RESET VIDEO 12V DI GND DO 485 485 1 2 3 4 5 6 Color Green 8 1 Green LED Orange LED Color Pink ...

Page 8: ...onnect to sensor in and alarm out devices Cable for I O connectors Name Number Function 12VDC 1 DC 12V 50mA maximum DI 2 Digital signal input GND 3 GND DO 4 Digital signal output 485 5 RS485 data 485 6 RS485 data MIC in Audio in Connect a microphone to the network camera Audio out Connect a loud speaker to the network camera This function is for voice alerting and two way audio Video out BNC conne...

Page 9: ... and reboot again Note Restoring the factory default setting will lose the all previous settings included IP address forever User needs to run the IPWizard II program to search the device and configure it to let the device work properly again 2 2 3 Installation 1 Fix IR camera to desired location with wall mount fixture 2 Plug in Ethernet Cable into RJ 45 connector Connect an Ethernet cable to the...

Page 10: ...1 Accessory Kit x 1 User s Manual CD x 1 Quick Installation Guide x 1 Note If any of the above items are missing please contact your dealer immediately 2 3 2 Physical Details ICA 8350 Connector DI DO MIC AUDIO DC RJ 45 RESET VIDEO 12V DI GND DO 485 485 1 2 3 4 5 6 Color Green 8 1 Green LED Orange LED Color Pink ...

Page 11: ...Connect to sensor in and alarm out devices Cable for I O connectors Name Number Function 12VDC 1 DC 12V 50mA maximum DI 2 Digital signal input GND 3 GND DO 4 Digital signal output 485 5 RS485 data 485 6 RS485 data MIC in Audio in Connect a microphone to the network camera Audio out Connect a loud speaker to the network camera This function is for voice alerting and two way audio Video out BNC conn...

Page 12: ... and reboot again Note Restoring the factory default setting will lose the all previous settings included IP address forever User needs to run the IPWizard II program to search the device and configure it to let the device work properly again 2 3 3 Installation 1 Fix IR camera to desired location with wall mount fixture 2 Plug in Ethernet Cable into RJ 45 connector Connect an Ethernet cable to the...

Page 13: ...l help you to configure some basic setting before you started advanced management and monitoring Please insert the bundle CD disk into your CD DVD ROM drive When the welcome web page appears please click your IP camera name on the IP camera list Then click the PLANET IPWizard II hyperlink to start the PLANET IPWizard II Search function Press Search button PLANET IPWizard II will list all networked...

Page 14: ...of the installed network devices User can step by step to setup IP address username and password Note 1 If no IP address is assigned within 30 seconds the networked device will automatically assign 192 168 0 20 User may now open your web browser and key in http 192 168 0 20 in the address bar of you web browser to logon IP Camera s web configuration page 2 Power Line Frequency If you found the vid...

Page 15: ... Default Password admin Default IP 192 168 0 20 if no DHCP existed in the network If difficulty is met please refer to the following steps to establish the connection The networked device must be installed and powered ON If the networked device s default IP Address 192 168 0 20 is already used by another device the other device must be turned OFF until the device is allocated a new IP Address duri...

Page 16: ...16 Further Information This guide is used to help you startup your IP Camera settings It is also recommended to check the user manual in CD disk for more details of the system and user configuration ...

Reviews: