![Planet FSD-1020 Manual Download Page 42](http://html1.mh-extra.com/html/planet/fsd-1020/fsd-1020_manual_1563205042.webp)
Operation 3-23
FSD-1020 User's Manual
Disable
Enter and hold
Back
Enter
Table 3.8 Loop Isolation.
Flow Control
Flow Control is another important feature supported by Desktop Switch
FSD-1020. This feature provides a back-pressure method of preventing any
packet loss
,
controlling the buffer-memory usage on every port effectively. It
is disabled at the time of shipment from the manufacturer. You have to enable
the function through the Mini-Console. The command sequence is:
UNIT CONFIG > FLOW CONTROL > ENABLE><Enter and hold>
Long Frame
The system can check the length of each packet sent. Packets larger than the
range 1024~1518 bytes are long frames. When set to Enabled, Long Frames
will be counted. When set to Disabled, Long Frames will be not be counted.
Lock the Console
Setting this option to
Enable
locks the system settings. If there is no password
set, a prompt will request one be entered.
UNIT CONFIG > CONSOLE LOCK> ENABLE><Enter and hold>
If User Password has been set and the Lock Function “Enabled”, the unit
does not allow any settings to be changed, such as port setting and unit
configuration, unless the correct password is keyed in and the
Summary of Contents for FSD-1020