42
This field allows the user to Enable or Disable the RIP session. The resulting RIP
session will monitor all network interfaces that are currently available for messages
from other RIP routers.
Supplier Interval
This field allows the user to enter the Supplier Interval timer in second. This timer
specifies how often RIP sends announcements as a RIP Supplier.(Default = 30
seconds)
Expire Timeout
This field allows the user to enter the Expire timer in second. This timer specifies
the expiration time of a route. When a route has not been updated for more than
“
expire
”
period of time, it is removed from the Route Table. This route is invalidated
and remains in the internal RIP Route Table. It will be included in the RIP an-
nouncements to let other routers know the changes. (Default = 180 seconds)
Garbage Timeout
This field allows the user to enter the Garbage timer in second. This timer specifies
how long the expired and invalidated routes are kept in the Internal RIP Route
Table before it is removed from it. (Default = 300 seconds)
RIP Per Interface Configuraiton
The RIP Per Interface Configuration page allows the user to set the configuration
for each Interface (PVCs, PPP Sessions, and LAN).
Figure 6-8:
RIP Per Interface Configuration Screen
Interface
This field allows the user to choose the Interface (PVCs, PPP Sessions, USB and
LAN), for the RIP to be configured.
Enable
This field allows the user to Enable (Yes) or Disable (No) the specified interface for
RIP.
Supplier
This field allows the user to select the Supplier Mode (RIP Transmit).
•
Disabled: The supplier transmit is disabled.
•
V1 BC: The supplier transmits in RIPv1 Broadcast.
•
V2 BC: The supplier transmits in RIPv2 Broadcast.