EL640.400-CB1/CB3 and –CD4 Operations Manual (020-0356-00A)
6
Jumper Description
Table 3. PS1.
Position Name
Function
1 SELFTST
Self test function is selected, if the SELFTEST jumper is ON. In self test,
the input video data at VID and TVID inputs are displayed
asynchronously without any other input signals.
2 F2040
200 lines mode. All data is repeated in two consecutive rows.
Normally should not be installed
3 DCONFIG
The Two-bits-parallel mode is selected if this jumper is set (see page 10.)
4
Reserved.
When shipped from the factory, no jumpers are set.
Input Specifications
Table 4. Input Specifications.
Parameter
Symbol
Min.
Typ.
Max.
Absolute
max. rating
Logic input HIGH
Logic input LOW
Logic supply voltage
Logic supply current at 5 V
Display Supply voltage (CB1, CD4)
(CB3)
Supply current at +12 V (CB1, CD4)
Supply current at +24 V (CB3)
Power consumption 5 V & 12 V
Power consumption 5 V & 24 V
Vcc1
Icc1
Vcc2
Vcc2
Icc2
Icc2
2 V
4.75
V
—
10.8
V
21.6
V
—
—
—
—
5.0 V
—
12 V
24 V
0.8 A
0.5 A
11 W
13 W
0.8 V
5.25
V
0.2 A
14.4
V
26.4
V
1.5 A
0.8 A
19 W
20 W
Vcc1 + 0.5 V
–0.5 V
6 V
15 V
30 V
Operating conditions: Frame rate 70 Hz. ambient temperature 25°C.
Note: Absolute maximum ratings are those values beyond which damage to
the device may occur. The minimum and maximum specifications in this
Operations Manual should be met, without exception, to ensure the long-
term reliability of the display. Planar does not recommend operation of the
display outside these specifications.
For ordering information of EL640-400-CB1 and other EL Displays, please visit http://www.eldisplays.com/EL640-400-CB1 or call +1-888-394-4998.