15
EL640.400-CB1/CB3 and –CD4 Operations Manual (020-0356-00A)
Operational Specifications
Environmental
Table 10. Environmental Characteristics.
Temperature
Operating
0…+55°C
Non-operating –40…+85°C
Operating Survival
–20…+65°C (no permanent damage)
Test duration 24 h at -20°C (without condensation)
Humidity
Relative Humidity
+40°C, 93% RH, Operating (IEC 68-2-3)
Damp Heat
+25…+55°C, 95% RH, Non operative (IEC 68-2-30)
Altitude
Operative
15,000 m (50,000 ft.) above sea level
Vibration
20…500
Hz
ASD level 0.05 G
2
/Hz
Random vibration wide band
IEC 68–2–36, Test Fdb
Shock
Magnitude
Duration
Number of shocks
100 G
4 ms (half sine wave)
18 (3 on each of the 6 surfaces)
IEC 68-2-27, test Ea
Reliability
MTBF > 50000 h @ 25°C
Safety
The display will not inhibit the end product from obtaining any of the
following specification: UL1950, UL544, CSA154, IEC 950
EMC
The display will not inhibit the end product from obtaining any of the
following specifications: EN55022 Class B, FCC Part 15J Class B
For ordering information of EL640-400-CB1 and other EL Displays, please visit http://www.eldisplays.com/EL640-400-CB1 or call +1-888-394-4998.