background image

 

EL512.256-H Series Operations Manual (020-0354-00A)

 

12 

Mechanical Characteristics 

Display External Dimensions 

Fig. 6 shows the mechanical dimensions of a standard EL512.256–H series 
display unit. The display can also be delivered with optional FRA aluminium 
frame or FRB steel frame (see Fig. 5 and 6). Using FRB frames makes the display 
mounting compatible with Planar MD512.256 displays. See Ordering 
Information on page 19. 

Table 9. Display External Dimensions. 

Height  

136 mm 

5.35 in. 

Width  

233 mm 

9.17 in. 

Depth  

16.5 mm 

0.65 in. 

Weight  

400 g  

14 oz. 

Display Viewing Area Characteristics 

Table 10. Display Viewing Area Characteristics. 

 

Active Area 

millimeters (inches)  
 

 

height 97.5 

(3.84) 

width 195.1 

(7.68)

 

 

Pixel Pitch  

millimeters (inches)

 

 
height 0.381 

(0.015) 

width 0.381 

(0.015) 

 

Pixel Size 

millimeters (inches)

 

 
height 0.25 

(0.01) 

width 0.25 

(0.01) 

 

Pixel fill factor 

43% 

 

Pixel Matrix 

512  horizontal by 256  vertical 

 

CAUTION: The ambient temperature of the display should not be allowed to 
exceed the environmental specifications (see Table 7). In most applications, 
an air gap of appr. 5 mm is recommended (see mechanical drawings). Some 
applications may require, however, a larger air gap or cooling of the display 
unit in the system. Note that this may slightly increase the total depth of the 
design. 

 

 

For ordering information of el512-256-h3-frb and other EL Displays, please visit http://www.eldisplays.com/el512-256-h3-frb/ or call +1-888-394-4998.

Summary of Contents for EL512.256-H Series

Page 1: ...s 512 x 256 Pixel Electroluminescent Display USER S MANUAL www planar com For ordering information of el512 256 h3 frb and other EL Displays please visit http www eldisplays com el512 256 h3 frb or ca...

Page 2: ...tion April 1995 Document number PI02552 Ver 1 June 2004 Document number 020 0354 00A For ordering information of el512 256 h3 frb and other EL Displays please visit http www eldisplays com el512 256 h...

Page 3: ...f Test 8 Installation and Handling 9 Video Input Timing 10 Setup and Hold Timing 10 Operational Specifications 11 Environmental 11 Reliability 11 Safety 11 Optical 12 Display Colour 12 Optional Filter...

Page 4: ...d Side Views with FRB Steel Mounting Frame 17 Tables Table 1 Input to the Display 5 Table 2 Connectors 6 Table 3 PS1 7 Table 4 Input Specifications 7 Table 5 Video Input Timing 10 Table 6 Setup and Ho...

Page 5: ...displays require 5 Vdc and 11 30 Vdc power input and four basic input signals to operate 1 Video Data or pixel information 2 Video Clock pixel clock or dot clock 3 Horizontal Sync 4 Vertical Sync EL T...

Page 6: ...tage is applied to both the correct row electrode and the correct column electrode to cause a lit pixel Operating voltages required are provided by an integral DC DC converter Electrical Characteristi...

Page 7: ...al that supplies the pixel information to the system 12 14 16 Ground GND Signal return J2 Optional power input connector 1 Voltage Vcc2 Same as J1 Pins 1 2 not necessary to connect if power is supplie...

Page 8: ...nput for the video signals connector J2 contains two control inputs and connector J3 contains input for external luminance control The signals on J2 and J3 that are not used can be left disconnected O...

Page 9: ...0 5V abs min 6V abs max 33V abs max Operating conditions Frame rate 70 Hz ambient temperature 25 C Note Absolute maximum ratings are those values beyond which damage to the device may occur The minim...

Page 10: ...d 100 by an external 50 k logarithmic potentiometer between the LUMPOT1 and LUMPOT 2 inputs J3 pins 1 and 2 The control function is done by feeding a small DC current signal via the external potentiom...

Page 11: ...display input connector is recommended If longer cables up to 2m 80 in length are needed a serial resistor of appr 47 could be placed at each of the four signal line outputs of the transmitter in orde...

Page 12: ...period tHS 50 s Notes 1 This time is needed to display the last row and to change the frame 2 Only rising edge is used 3 Video Clock VCLK should be kept running 4 The values for two bit parallel mode...

Page 13: ...68 2 3 Damp Heat 25 55 C 95 RH Non operating IEC 68 2 30 Altitude Operating 15 000 m 50 000 ft above sea level Vibration 20 500 Hz ASD level 0 05 G2 Hz Random vibration wide band IEC 68 2 36 Test Fdb...

Page 14: ...ter and four corners Luminance Variation Time Maximum 20 10 000 h Luminance Variation Temperature Typical Maximum 10 15 over 25 65 C range Viewing Angle Minimum 160 Optional Filter For best overall op...

Page 15: ...rea Characteristics Active Area millimeters inches height 97 5 3 84 width 195 1 7 68 Pixel Pitch millimeters inches height 0 381 0 015 width 0 381 0 015 Pixel Size millimeters inches height 0 25 0 01...

Page 16: ...0354 00A 13 Fig 5 Viewing Area Characteristics Fig 6 Front View without Mounting Frame standard For ordering information of el512 256 h3 frb and other EL Displays please visit http www eldisplays com...

Page 17: ...perations Manual 020 0354 00A 14 Fig 7 Back and Side Views Dimensions in mm For ordering information of el512 256 h3 frb and other EL Displays please visit http www eldisplays com el512 256 h3 frb or...

Page 18: ...020 0354 00A 15 Fig 8 Back and Side Views with FRA Aluminum Mounting Frame Dimensions in mm For ordering information of el512 256 h3 frb and other EL Displays please visit http www eldisplays com el5...

Page 19: ...l 020 0354 00A 16 Fig 9 Back and Side Views with FRB Steel Mounting Frame Dimensions in mm For ordering information of el512 256 h3 frb and other EL Displays please visit http www eldisplays com el512...

Page 20: ...ted insufficient Seller shall refund Buyer s paid price for the Goods and have no other liability to Buyer All warranty repairs must be performed at Seller s authorized service center using parts appr...

Page 21: ...ark the outside of the shipping container with the RMA number Ordering Information Product Part Number Description EL512 256 H2 E0051240022 0 55 C operating temperature range EL512 256 H2 FRA E0051240...

Page 22: ...nland Tel 358 9 420 01 Hours M F 7 00am 4pm CET 2004 Planar Systems Inc 06 04 Planar is a registered trademark of Planar Systems Inc ICE ICEBrite and ICEPlus are trademarks of Planar Systems Inc Other...

Reviews: