EL320.240.36-HB Operations Manual (020-0346-00A)
4
Cable Length
A maximum cable length of 0.6 m (24 in.) is recommended. Longer cables may
cause data transfer problems between the data transmitted and the display
input connector. Excessive cable lengths can pick up unwanted EMI. There are
third party products which allow this maximum cable length to be exceeded.
Contact Planar Application Engineering for more information.
Cleaning
As with any glass or coated surface, care should be taken to minimize
scratching. Clean the display glass with mild, water-based detergents only.
Apply the cleaner sparingly to a soft cloth, then wipe the display. Disposable
cleaning cloths are recommended to minimize the risk of inadvertently
scratching the display with particles embedded in a re-used cloth. Particular
care should be taken when cleaning displays with anti-glare and anti-reflective
films.
Avoiding Burn-In
As with other light emitting displays, use a screen saver or image inversion to
avoid causing burn-in on the display. Displaying fixed patterns on the screen
can cause burn-in, where luminance variations can be noticed.