Troubleshooting
Problem
Possible Cause
Possible Solution
The battery system not functioning,
no output power, does not charge
when connected to AC power.
AC power is not connected.
Make sure power cord is connected properly.
Input fuse needs to be replaced.
Replace fuse in the input AC connector.
Replace with UL-recognized fuse 2 A,
250 VAC, fast acting, size 5 mm x 20 mm.
Over-temperature protection is activated.
Contact Planar.
No power supplied to the load.
Output power cord not connected properly.
Make sure that output power cord is
connected correctly.
Power switch is off.
Turn on the power switch on your device.
Output fuse needs to be replaced.
Replace the output power fuse located next
to output power connector. Replace with
UL-recognized fuse 6 A, 125 VDC, fast acting,
size 0.25 in. x 1.25 in., type F.
Batteries not connected correctly.
Check battery connections.
System run time is too short.
Battery not completely charged.
Connect AC power and let battery charge
completely. Charge status is conveyed
through the
on the
Power Options Properties dialog Note that
the LED turns green at 80% of total charge
capacity.
Battery capacity is low.
Replace battery.