Fireplace operation in transitional periods
During the transitional periods (when external temperature exceeds 15° C), problems may be
encountered due to insufficient negative pressure (poor or no draught) in the chimney. In such a
case, try to achieve necessary draught by warming up the chimney. If this does not work, do not
proceed with the firing. Opening of a window or a door of the room during the firing might help to
equalize the internal and external air pressure
.
Maintenance and cleaning
At the end of each heating season, clean the fireplace, fluepipes and chimney from soot deposits.
Regular inspection and cleaning are essential for preventing the risk of chimney fire. In case of
chimney fire, proceed as follows:
-
never use water to extinguish the fire
-
close all air supply passages to the fireplace and chimney
-
having extinguished the fire, call the chimney sweeper to inspect the chimney
-
call the manufacturer's authorised service to inspect the fireplace.
The door glass may be cleaned with ordinary window glass cleaners.
Should any problems occur during the operation (e.g. smoke), contact your chimney sweeper or
the closest local Service. Any repair/maintenance works on the fireplace shall be performed by
authorised service personnel and only original spare parts shall be used.
Warranty
The Manufacturer's warranty shall apply provided that the fireplace is used in accordance with
these Installation and Operating Instructions.
Space heating capacities
The size of the heated space depends on the heating conditions and thermal insulation.
Subject to the heating conditions, with individual heat sources of rated output 8
,6
kW, it is possible
to heat up the following space volumes:
- under favourable conditions
180
m³
- under less favourable conditions
120
m³
- under unfavourable conditions
85 m
³
Occasional heating or intermittent heating should be considered as less favourable or even
unfavourable heating conditions.
Chimney dimensioning should be based on the following data:
It's used for cleaning enamel and painted parts using soap and water, non-abrasive or chemically
non-aggressive detergents.
Rated heating output
Flue gas flow rate [m]
Mean flue gas temperature downstream the flue connection
Minimum required negative pressure in the chimney [p] at rated output
Minimum required negative pressure in the chimney [p] at 0.8-times rated output
kW
g/s
mbar
mbar
°C
18
8,6
0,14
0,11
9,3
307
Summary of Contents for Banrum
Page 33: ...x x 728x840x520 mm 185 kg 8 6 kW 180 mm bay pass 1 kW 10 m 2 5 180mm 180 mm 250 cm 5 6 0 5 33...
Page 34: ...10 20 25 cm 2 3 2 kg 2 3 a 5 10 34...
Page 35: ...3 4 kg 11 12 kW 8 6 kW 35...
Page 36: ...15 C 8 6 kW 180 m 120 m 85 m a m p e p 0 8 kW g s mbar mbar C 36 8 6 0 14 0 11 9 3 307...
Page 39: ...728x840x520 mm 185 8 6 kW 180 mm bay pass 1 W 10 m 2 5 180 180 250 m 5 6 0 5 39...
Page 40: ...20 25 2 3 2 2 3 5 10 40...
Page 41: ...3 4 11 12 kW 8 6 kW 41...
Page 42: ...15 C 8 6 kW 180 m 120 m 85 m m p p 0 8 8 6 0 14 0 11 kW g s mbar mbar C 42 9 3 307...