PKP PMR06 Instruction Manual Download Page 7

Options and Accessories:

Description:

Code

for type PMR06…

Design for increased safety

(break-proof partition wall and

blow-out rear wall)

ES

x.E…, unfilled,

not for NG 250,

only model A, B

Front ring polished

FP

models B,E,F

Tropical-proof housing

GT

only unfilled devices

Pointer movement stainless steel

ZE

x.M… unfilled

Multiple scale

SM

all types

Scale label

SA

all types

Cliché creation for special scale
(1-colored or multicolored)

SS1

SSx

all types

Measuring system free of oil and grease 

for oxygen

MO

all types

Measuring system silicone-free

MS

all types

Glycerine filling

FG

all types

Throttle screw in connection,
d = 0,8 or 0,3 mm

D08

D03

all types

Process connection G 1/4 female, M20 x 

1,5, small flange DN10, stainless steel

Px

all types

only x.E...

Red stamp on dial

MR

all types

Red mark pointer in the sight glass

ZR

all types

Slave pointer, resettable,
1-fold or 2-fold

ZS1

ZS2

all types

Pointer with toothed drive adjustment

ZZ

all types

Calibratable acc. to calibration regulations

E

all types

Transport case with manometer,
shut-off valve and accessories

TK

only NG 160

Dimensions:

Dimensions:

Value [mm]

NG 160

NG 250

b

50

55

b1

56

61

b2

88

93

c

14,5

16

c1

50

50

D

161,3

251

d1

178

271

d2

196

285

d3

5,8

5,8

d4

166

-

h

118

165

SW

22

22

Weight [kg]

1,1

2,2

Models:

model A:
connection at bottom

model B:
connection at bottom,
rim at front

model C:
connection at bottom,
rim at back

model D:
connection at back

model E:
connection at back,
rim at front

Panel cut-out:
NG 160: 165 mm
NG 250: 254 mm

model F:
triangular front ring and
mounting bracket

Panel cut-out:
NG 160: 163 mm
NG 250: /

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

Summary of Contents for PMR06

Page 1: ...Instruction Manual PMR06 Precision Bourdon Tube Pressure Gauge PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Page 2: ...application must also be observed This statement also applies to the use of accessories 2 2 Proper Usage Series PMR06 pressure gauges are designed for measuring different process pressures Any applica...

Page 3: ...tapping point then the process line must be thoroughly flushed out first to remove any foreign objects before the gauge is installed Some device models have a pressure relief opening that can be vent...

Page 4: ...itable equipment Caution If the pressure gauge is being used to monitor hazardous substances such as oxygen acetylene flammable or combustible materials or poisonous materials and or being used in ref...

Page 5: ...age in a greatly reduced form The wear of the moving parts is also reduced by the natural lubrication of the filling liquid and the penetration of corrosive gases and the formation of condensation wat...

Page 6: ...60 mm 25 250 mm Materials M housing stainless steel connection brass E housing stainless steel connection stainless steel S special material please specify in plain text Process connection 1 G 1 2 bot...

Page 7: ...E Red stamp on dial MR all types Red mark pointer in the sight glass ZR all types Slave pointer resettable 1 fold or 2 fold ZS1 ZS2 all types Pointer with toothed drive adjustment ZZ all types Calibr...

Page 8: ...g sleeve M20x1 5 LH RH acc to DIN 16238 intermediate piece with test flange and accessories fork for test flange solid transport case test report Dimensions PMR06 16 with shut off valve and clamping s...