5 Maintenance

Mechanical pressure gauges are maintenance-free.
The measuring accuracy (as defined per DIN EN 837) of the pressure gauge should be
checked regularly. Inspection or recalibration should only be performed by trained, qualified
personnel with suitable equipment.

Caution: 

If the pressure gauge is being used to monitor 

hazardous substances

 such

as oxygen, acetylene, flammable or combustible materials, or poisonous materials
and/or being used in 

refrigeration systems, compressors

, etc., then the regulations

applying in such cases must be also be observed in addition to the ones generally
applicable. Be sure to take appropriate precautions and follow proper safety
procedures.

PMR06-~1.SAM

 

18.05.06 Page 4

Summary of Contents for PMR06

Page 1: ...Instruction Manual PMR06 Precision Bourdon Tube Pressure Gauge PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Page 2: ...application must also be observed This statement also applies to the use of accessories 2 2 Proper Usage Series PMR06 pressure gauges are designed for measuring different process pressures Any applica...

Page 3: ...tapping point then the process line must be thoroughly flushed out first to remove any foreign objects before the gauge is installed Some device models have a pressure relief opening that can be vent...

Page 4: ...itable equipment Caution If the pressure gauge is being used to monitor hazardous substances such as oxygen acetylene flammable or combustible materials or poisonous materials and or being used in ref...

Page 5: ...age in a greatly reduced form The wear of the moving parts is also reduced by the natural lubrication of the filling liquid and the penetration of corrosive gases and the formation of condensation wat...

Page 6: ...60 mm 25 250 mm Materials M housing stainless steel connection brass E housing stainless steel connection stainless steel S special material please specify in plain text Process connection 1 G 1 2 bot...

Page 7: ...E Red stamp on dial MR all types Red mark pointer in the sight glass ZR all types Slave pointer resettable 1 fold or 2 fold ZS1 ZS2 all types Pointer with toothed drive adjustment ZZ all types Calibr...

Page 8: ...g sleeve M20x1 5 LH RH acc to DIN 16238 intermediate piece with test flange and accessories fork for test flange solid transport case test report Dimensions PMR06 16 with shut off valve and clamping s...

Reviews: