PKP DU06 Series Instruction Manual Download Page 13

Models:

DU06.M… 

brass version, housing made of brass
2.0401, sensors made of stainless steel
1.4571, FKM gaskets, (EPDM optional),
for 1/2" pipe only

DU06.E…

 

stainless steel version, housing made of
stainless steel 1.4571, sensors made of
stainless steel 1.4571, FKM gaskets,
(EPDM optional), for 1/2" to 2" pipe

Measuring ranges:

Measuring
range *)

Brass-

version

St. steel-

version

Process-

connection

0,5…80 l/min

DU06.M…R015 DU06.E...R015

R 1/2 male

1…180 l/min

-

DU06.E…R025

R 1 male

8…1000 l/min

-

DU06.E…R050

R 2 male

*) Maximum ranges are specified. For a higher resolution the 
output can be programmed for end values < max. measuring 
range

Electrical Data:

Output signal:

adjustable on site: 4...20 mA, 0...10 V
or frequency output
and 2 limit relays

Connection 4 pin plug: Power supply, output signal

Pin 1: 4-20 mA / 0-10 V / frequency output
Pin 2: GND
Pin 3: GND
Pin 4: +24 VDC ±15%

Connection 6 pin plug: Relay output

Pin 1: relay 2, N/O contact
Pin 2: relay 2, common contact
Pin 3: relay 2, N/C contact
Pin 4: relay 1, N/O contact
Pin 5: relay 1, common contact
Pin 6: relay 1, N/C contact

Dimensions:

Order Code:

Order number:                         DU06.

Ultrasonic flowmeter and counter
with local indication

E. V. R025. 0. 0

Material version:

M = brass housing, sensors st. steel

   (with R ½ male connection only)

E = st. steel housing, sensors st. steel
S = special version

Gaskets:

V = FKM (standard)
E = EPDM
S = special gasket

Measuring range / Process connection:

R015 = 0,5…80 l/min, R ½ male
R025 = 1…180 l/min, R 1 male (only DU06.E…)
R050 = 8…1000 l/min, R 2 male (only DU06.E…)

Output signal:

0 = universal output for power, voltage or frequency,

adjustable on site
and 2 limit relays

Options:

0 = without
9 = please specify in plain text

Technical Data:

Max. pressure:

25 bar

Medium temperature:

−20...+100 °C

Ambient temperature:

−10...+60 °C

Accuracy:

± 2% of full scale

Mounting position:

any, rotatable housing

Medium:

acoustically conductive liquids,
solids content < 10 Vol.%

Power supply:

24 VDC ± 15%

Power consumption:

200 mA max.

Outputs:

4…20 mA, 0…10 V, frequency-
output (programmable,
max. 32 kHz),
Ri = 2 kOhm

Limit value relay:

2 x changeover cont., 30 VDC / 1 A

Display:

LCD, 2 x 16 digit, illuminated

Protection class:

IP65

Response time:

0,8...8 s, factory setting ca. 1,6 s

Flow direction:

adjustable in device

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

Summary of Contents for DU06 Series

Page 1: ...Instruction Manual DU06 Ultrasonic flowmeter with display PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email info pkp de...

Page 2: ...vent of damage due to improper use non observance of this operating manual use of insufficiently qualified personnel and unauthorized modification of the device Proper Usage The ultrasonic flow meter...

Page 3: ...on versions are available version made of brass or stainless steel flow max 80 l min 1 version made of stainless steel flow max 180 l min 2 version made of stainless steel flow max 1000 l min All vers...

Page 4: ...urrent voltage frequency output 4 pole plug included in delivery Pin 1 4 20mA 0 10V Freq Out Pin 2 GND Pin 3 GND Pin 4 24VDC 15 Relay outputs 6 pol plug included in delivery Pin 1 Relay 2 normally ope...

Page 5: ...parameter Output Parms Menu 1 Relay 1 setting switch point of relay 1 Relay 2 setting switch point of relay 2 If the actual measured flow exceeds falls below one of the adjusted switch points the re...

Page 6: ...erated Freq Out 0 Hz is generated Assignment of analog output signal If the analogue output is used the following assignment must be observed 20 mA corresponds to the Max Flow Limit 4 mA corresponds t...

Page 7: ...c Litre per second l min Litre per minute l h Litre per hour m min Cubic meter per minute m h Cubic meter per hour gal sec Gallons per second gal min Gallons per minute gal h Gallons per hour Percent...

Page 8: ...e flow passing the DU06 during power failure was not counted Parameter protection Pin Pin Code is for protecting parameter of the device Changing them without authority will be avoided If the Pin is a...

Page 9: ...fset This function is used for adaption of the characteristic diagram up to formula Qkorr Qist DynOffset Qist QmaxPhys With Qist measured flow Qkorr corrected flow QmaxPhys max flow in pipe at v 5m se...

Page 10: ...s and protected due to manufacturers code 4 20 mA K value of current output 4 20 mA K Value This function is for special applications and protected due to manufacturers code 0 10 V K value of voltage...

Page 11: ...dium The DU06 indicates no negative flow If there is 0 flow indication while there is flow flow direction has to be changed in the program Functional check It is the responsibility of the operator to...

Page 12: ...time difference is proportional to the flow rate In contrast to other types of ultrasonic flowmeters the sensors are oriented parallel to the flow stream This results in an extremely compact meter wh...

Page 13: ...Dimensions Order Code Order number DU06 Ultrasonic flowmeter and counter with local indication E V R025 0 0 Material version M brass housing sensors st steel with R male connection only E st steel ho...

Reviews: