Measuring range, materials and models
DR08-15
Order number: DR08-15
Miniature turbine flowmeter
for low viscosity media
S. K. I. P. 0. 0. A. H
Measuring range:
S = 2…40 l/min
(continuous operation max. 20 l/min)
Material:
K = PPE Noryl housing (not for
high pressure version)
M = brass housing
V = stainless steel housing (only in high pressure
version P)
Model:
I = with inductive sensor (not in stainless steel)
H = with Hall sensor
P = with Hall sensor up to 300 bar, 150 °C
(high pressure version)
Output signal:
P = PNP (with inductive sensor only)
N = NPN
M = transmitter (with option Ax, VE, VEP)
Electrical connection:
P = 1,5 m PVC cable
L = 1,5 m silicone cable (only for high temp. version P)
S = plug connection M12x1, 4-pin (without mating connec.)
Additional temperature sensor:
0 = without
1 = Pt100 in brass case
2 = Pt100 in stainless steel case
3 = Pt1000 in brass case
4 = Pt1000 in brass case
Process connection (con. adapter recommended):
A = G 3/4 male thread (Standard)
I = G 3/4 female thread (only for high pressure-
version P in stainless steel)
Connection adapter according to table „Connection adapter“
(separate position)
Options:
0 = without
H = with integrated sieve filter, 0,5 mm (Tmax. 60 °C), POM, st. steel
Ax = with mounted transmitter
4…20 mA (x = measuring range end value
5, 10, 20 or 40 l/min)
VE = with mounted switching output
VEP = with mounted switching output
and additional pulse output
(5-pin connector required)
Technical Data:
Materials:
DR08-15.x.K:
flow housing and sensor:
PPE Noryl GFN3
turbine insert and impeller:
PEI ULTEM
O-ring: NBR, optional FKM
bearing / axle: ARCAP AP1D with
tungsten carbide pins and
sapphire bearings
impeller assembly: hard ferrite magnet
for Hall sensor, st. steel for inductive
sensor transducer
Materials (continued):
DR08-15.x.M:
flow housing: brass
transducer: PPE Noryl GFN3,
brass for high pressure version
turbine insert and impeller:
PEI ULTEM, PEEK Victrex bei
high pressure version
O-ring: NBR, optional FKM
bearing / axle: ARCAP AP1D with
tungsten carbide and sapphire bearings
impeller assembly: hard ferrite magnet
for Hall sensor, st. steel for inductive
sensor
DR08-15.x.VP:
flow housing: stainless steel 1.4571
transducer: stainless steel 1.4571
turbine insert and impeller:
PEEK Victrex
O-ring: FKM
bearing / axle: ARCAP AP1D with
tungsten carbide and sapphire bearings
impeller assembly: hard ferrite magnet
max. pressure:
DR08-15.x.K:
PN 10
DR08-15.x.M.I / H:
PN 10
DR08-15.x.M.P:
300 bar (up to 150 °C)
DR08-15.x.V:
300 bar (up to 150 °C)
max. medium temperature:
DR08-15.x.K:
85 °C
DR08-15.x.M.I / H:
85 °C
DR08-15.x.M / V.P:
150 °C
accuracy:
DR08-15.x.x.H:
± 1 % of full scale
DR08-15.x.x.P:
± 1 % of full scale
(bis 20 l/min)
DR08-15.x.x.I:
± 0,5 % of full scale
repeatability:
DR08-15.x.x.H/P:
± 0,1 l/min
DR08-15.x.x.I:
± 0,05 l/min
supply:
DR08-15.x.x.H / P:
4,5…24 VDC
DR08-15.x.x.I:
10...30 VDC
output signal:
DR08-15.x.x.H / P:
square-wave pulses,
855 (H) / 915 (P) ppl
NPN open collector
max. 10 mA signal current
DR08-15.x.x.I:
square-wave pulses , 1795 ppl
NPN or PNP open collector
max. 50 mA signal current
signal output:
from 0,3 l/min
max. particle size:
0,5 mm
protection class:
IP54
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S
+49 (0) 6122-7055-0 •
T
+49 (0) 6122 7055-50