49
~
9.
Fix the upper chimney (
P
) using 4*10 screws on the fixing bracket (
Q
/ s. fig.
below).
P
U
PPER CHIMNEY
Q
2
SCREWS
(4*10)
10.
Insert the grease filters and connect the appliance to the mains
13
.
Check the correct position of the hood from front and side perspective.
Otherwise, the appliance will not work properly.
2.5 Electrical connection
Check that the voltage indicated on the rating plate matches the mains voltage of
your home before connecting the extractor hood to the mains. The rating plate (
A
)
is inside the extractor hood, next to the motor (s. fig. below). To gain access to the
rating plate (
A
), you must open the extractor hood using the « O
PEN
»
-
BUTTON
(
X
/ see fig. below.
13
If the socket is covered by the chimney, you must plug in the appliance at an earlier point in time.