144
~
D
S
OCKET SPANNER
E
B
URNER
-
JET
(for
LPG
/
propane gas)
6.
The gas burners do not need a primary air regulation.
7.
Replace the gas burners in the correct position and reinstall the burner crowns,
burner caps and pot grids properly.
8.
Adjust the burner-jets for LPG to minimal-flame (minimum level): s. chapter
2.9.2 LPG:
ADJUSTMENT OF THE BURNER
-
JETS TO MINIMAL
-
FLAME
.
2.9.1 LPG: table of burners and burner-jets characteristics
Please refer to the chapter « T
ECHNICAL DATA
» for the
specific type of LPG
that is relevant for your appliance.
T
YPE OF
LPG
H
I
*
/
H
S
**
S
MALL
BURNER
M
EDIUM
BURNER
B
IG
BURNER
T
RIPLE
BURNER
(W
OK
)
G30-30 mbar
Hi
0.81 kW
1.49 kW
2.52 kW
2.79 kW
Hs
0.90 kW
1.65 kW
2.80 kW
3.10 kW
J
ET
(injector) Ø in mm
0.50
0.65
0.85
0.92
G31-37 mbar
Hi
0.81 kW
1.49 kW
2.52 kW
2.79 kW
Hs
0.90 kW
1.65 kW
2.80 kW
3.10 kW
J
ET
(injector) Ø in mm
0.50
0.65
0.85
0.92
G30-37 mbar
Hi
0.86 kW
1.58 kW
2.52 kW
2.97 kW
Hs
0.95 kW
1.75 kW
2.80 kW
3.30 kW
J
ET
(injector) Ø in mm
0.50
0.65
0.80
0.90
*
Hi
H
EATING VALUE
**
Hs
C