63
2.6.1
Connection diagram
Voltage heating elements 220
- 240 V.
Any kind of connection: the
safety
wire
must
be
connected to the
PE
terminal.
Recommended
type of
connection
lead.
1
➢
For 220 - 240 V earthed
one-phase connection.
➢
Bridges connect 1 - 2 - 3
terminals and 4 - 5
terminals.
➢
Protective ground to
H05VV-F3G4
2
➢
For 400 / 220 - 240 V
earthed
two-phase
connection.
➢
Bridges connect 2 - 3
terminals and 4 - 5
terminals, Neutral to 4 -
5
➢
Protective ground to
H05VV-F4G2,5
3
➢
For 400 / 220 - 240 V
earthed
three-phase
connection.
➢
Bridges connect 4 - 5
terminals, phases
in
succession 1, 2 and 3,
Neutral to 4 - 5.
➢
Protective ground to
H05VV-F5G1,5
L1=R, L2=S, L3=T
N= Earth
E= earth wire terminal
All supply circuits must be disconnected before accessing the terminals.
➢
For the connecting wires, the grounding wire must be longer than the other wires.
➢
Your domestic circuit must be equipped with an automatic circuit breaker.
➢
The appliance must be grounded.
➢
Check that the technical data of your energy supply meet the values on the
nameplate.