When the socket is not accessible for the user
or a fixed electrical connection
of the appliance is required
, an all-pole disconnecting device must be
incorporated during installation. Disconnecting devices are switches with a
contact opening distance of at least 3 mm. These include LS-switches, fuses and
protectors (EN 30335).
Connection diagram
1
For 220-240 VAC mains single-phase connection with operating neutral
conductor. Jumpers connecting the terminals 1-2-3. Jumpers to the terminals 4-5
for the operating neutral conductor.
Protective conductor on
H05VV-F 3G 6,0 mm
2
2
For 220-240 VAC mains two-phase connection with operating neutral conductor.
Jumpers connecting the terminals 1-2. Jumpers to the terminals 4-5 for the
operating neutral conductor.
Protective conductor on
H05VV-F 4G 6,0 mm
2