PJ Tech SMARTLIGHT 05 MK3 Operating & Maintenance Manual Download Page 7

 

Cap Lamp - SMARTLIGHT 05 Mk3 

Operating & Maintenance Manual 

 
 

CAP LAMP 

OPERATION 

 

Revision A 
 

Operating&Maintenance Manual SM-

05 Mk3 

Page 7 of 12 

 

 

4.1.3

 

Monitoring Battery Capacity 

After the lamp is switched on for the first time so is the microcontroller. At that time the 
microprocessor does not have any information about the state of the charge of the battery. The 
process of battery’s initial discharge is based on the voltage measurement. 
After the battery is discharged and subsequently fully charged all control of the charge level is 
maintained by the microcontroller which measures the flow of the electric charge from and to the 
battery. In parallel with the charge flow measurement the microcontroller monitors the time the 
diodes are switched on. During working cycle (lamp usage) from fully charged, the minimum time 
the MLED must be able to emit light at 100% intensity is 10 hours. After that time the base factor 
determining the functioning of the lamp is the amount of consumed charge. Once the total consumed 
charge reaches 9Ah the normal operation of the lamp is disabled. During this period ALED can be 
switched on for a period of 3 seconds at the time. During the lamp usage, in parallel with the used 
charge measurement the battery voltage is measured. Once the voltage drops below 3V then 
irrespective of the time the MLED is switched on or the amount of consumed charge the whole 
operation of the lamp is EMERGENCY DISABLED. 
During lamp usage the microcontroller indicates the following levels of discharge: 

 

80% discharge of the capacity dedicated to the lamp - MLED flashes 6 times 

 

99% discharge of the capacity dedicated to the lamp – MLED flashes 3 times 

 

Actual level of battery’s remaining capacity is constantly indicated by the ELED flashing as follows: 

 

81-100% capacity remaining – ELED flashes 5 times 

 

61 -80% capacity remaining – ELED flashes 4 times 

 

41-60% capacity remaining – ELED flashes 3 times 

 

21-40% capacity remaining – ELED flashes 2 times 

 

0-20% capacity remaining – ELED flashes 1 time 

The ELED flashes in the following pattern: 200ms – flash, 300ms pause, 2.5s pause between the 
cycles. 

4.2

 

Battery Charging 

4.2.1

 

Battery Chargers 

The SMARTLIGHT-05/M1 cap lamps to be charged only in the following charging devices: 
 

Charger Lamp 

Capacity 

Charger  

Type 

Part Number 

 

Charger module only 

(any charger type) 

PCL-SM05-CHRG/MOD 

Single (desktop) 

 

PCL-SM05-CHRG/1 

Stand alone  

(desktop or bench) 

PCL-SM05-CHRG/5 

17 

Row 

(part of PCL-SM05-CHRG/102) 

PCL-SM05-CHRG/17 

102 

Stand Alone 

 

PCL-SM05-CHRG/102 

 

IMPORTANT NOTE! 

 

All lamps are delivered with discharged and conditioned batteries 

To enable initial battery charge the electronic board with microcontroller must be connected to 

the battery by means of a connector under the battery casing cover (Figure 1-3) 

Summary of Contents for SMARTLIGHT 05 MK3

Page 1: ...esburg Republic of South Africa Tel 27 011 704 7088 9 Fax 27 011 704 7019 e mail lamps pjtech co za www www pjtech co za P O Box 928 Honeydew 2040 Johannesburg Republic of South Africa Revision A Oper...

Page 2: ...eration 6 4 1 2 Functioning of the Cable Continuity Voltage Monitoring 6 4 1 3 Monitoring Battery Capacity 7 4 2 Battery Charging 7 4 2 1 Battery Chargers 7 4 2 2 Initial Battery Charge 8 4 2 3 Standa...

Page 3: ...ging period 12 hours from completely discharged Light intensity at 1m from the lamp 3000 lux after 8 hours of 100 usage Light beam angle 120 deg Ingress protection IP 65 Level of protection explosion...

Page 4: ...nic board is equipped with the following Plug in Socket to connect the casing cover Figure 1 3 to the battery set Figure 1 1 Programmer unit can also be connected via the plug in socket Terminal Strip...

Page 5: ...th the battery set The body is enclosed by means of the threaded cover with the protective glass The threaded cover s tightness and possibility of unscrewing is ensured by means of the seal and lockin...

Page 6: ...rane switch Once the lamp is inserted into the charger within 30 seconds from entering capacity measuring mode an internal flag is activated and it is only deactivated once the battery is fully charge...

Page 7: ...tage drops below 3V then irrespective of the time the MLED is switched on or the amount of consumed charge the whole operation of the lamp is EMERGENCY DISABLED During lamp usage the microcontroller i...

Page 8: ...e calculated electric charge or Battery voltage 4 45V Once the charging cycle is completed the battery is being trickle charged by 20 of the interrupted current Note Discharging charging mode can also...

Page 9: ...ge life time of the NiMH battery is 800 cycles IMPORTANT NOTE Only authorized and adequately trained personnel can be allowed to perform the inspections and repairs Should the cap lamp malfunction in...

Page 10: ...er maintenance or accident and PJ Tech shall not be liable for any direct indirect consequential or incidental damages from use results of use or inability to use this product Within the warranty peri...

Page 11: ...able 5 Complete cable PCL SM05 ELK 25 492 4 16 Cable PCL SM05 ELK 25 578 13 Cable entry sleeve PCL SM05 ELK 35 191 14 Cable entry sleeve PCL SM05 ELK 35 192 15 Washer PCL SM05 ELK 10 148 15 Nut M18x1...

Page 12: ...be sent to the below Company Name PJ TECH Registration Number CK94 30139 23 V A T Number 4240179202 Contact Details Tel 27 011 704 7088 9 Fax 27 011 704 7019 e mail sales pjtech co za www www pjtech...

Reviews: