background image

© 2016 Cop

yr

ight Pizzato Elettr

ica - tr

anslation of the or

iginal instr

uctions

K8

K7

K7

K8

F

-

+

Tx

Ix

24 Vdc

OS1

OS2

K8

K7

K7

K8

F

-

+

Tx

Ix

24 Vdc

OS1

OS2

 13   INCREASE OF  THE NUMBER AND  THE LOADING CAPACITY OF  THE CONTACTS

If necessary it is possible to increase the number and the loading capacity of the 

output contacts by using external contactors with forced guided contacts.

Feedback circuit for external contactors 

with automatic start wiring

Feedback circuit for external contactors 

with manual or monitored start wiring

For a correct system operation any safety module or PLC connected to the electronic safety outputs 
OSx have to tolerate the pulse tests that are made on safety outputs .

 12  APPLICATION DIAGRAMS

- The sole use of proximity sensors type “pnp” is allowed;
- The duty cycle of each cam must make sure that at least one of the two sensors 

associated is always active; 

- prevent foreign bodies to penetrate between the proximity sensors and the cams 

thanks to proper installation, in order to avoid unwanted activations of the sensors.

- Install the two proximity sensors of the same axis in a way that makes them 

mechanically independent, in order to avoid a failure for simultaneous detachment of 
both sensors. For example, avoid fixing both sensors to a single bracket. 

- To detect the sense of the rotation, the two sensors referring to the same axis must 

be installed with a phase angle of 1/4 of the angle subtended by the tooth and the 
slot of each cam (example: if the phonic wheel has two teeth and two slots, the 
subtended angle of each cam is 180° and suggested phase angle is 45°). The tooth/
slot duty cycle  in any case must guarantee that at least one sensor is always active 
in any condition.

- The correct detection of each axis rotation sense must always be verified on the 

machine, because it is strongly influenced by: 
- Acceleration and angular speed of the axis
- Phase angle between the two sensors
- Cam shape (duty cycle)
- Reaction time of the sensors used

Application diagram for the safe detection of the movement of one or two rotating axes 

Led F1A Led F1B Led F2A Led F2B Description

/

/

/

/

Lack of power supply in the module.

green

green

green

green

Module start-up phase. 

orange

orange

orange

orange

Internal tests at start-up. 

green

*

*

*

The sensor connected to terminal F1A 
is active. 

*

green

*

*

The sensor connected to terminal F1B 
is active. 

*

*

green

*

The sensor connected to terminal F2A 
is active.

*

*

*

green

The sensor connected to terminal F2B 
is active.

blinking 

green

blinking 

green

blinking 

green

blinking 

green

During the rotation of the axes, LEDs 
F1A, F1B, F2A, F2B blink green at the 
same frequency of the signal received 
on the proximity sensors inputs. The 
voltage on A3-A4 terminals is correct. 

alternate 

red / 

green

alternate 

red / 

green

alternate 

red / 

green

alternate 

red / 

green

Voltage on A3-A4 terminals is out of 
the allowed range (example: terminal 
detachment, sensors failure) 

red

red

red

red

Board internal error. 

 14  DISPOSAL

At the end of service life product must be disposed of properly.

 15  SUPPORT

The device has been created for safeguarding people’s physical safety, therefore in 
case of any doubt concerning installation or operation methods, always contact our 
technical support service:

Pizzato Elettrica Srl - Italy
Via Torino, 1 - 36063 Marostica (VI)
Tel39.0424.470.930
Fax +39.0424.470.955
E-mail [email protected]
www.pizzato.com

Our support service provides assistance in Italian and English.

 16 EC CONFORMITY DECLARATION

I, the undersigned, as a representative of the following manufacturer:
Pizzato Elettrica s.r.l. , Via Torino, 1 - 36063 Marostica (VI) - Italy
hereby declare that the product is in conformity with whatever prescribed by the 2006/42/
EC Machine Directive. The complete version of the present conformity declaration is 
available on our site www.pizzato.com    
Mr. Pizzato Giuseppe

DISCLAIMER:

Rights to any modifications reserved without prior notice and errors excepted. The data mentioned on 

this sheet are accurately checked and represent typical mass production values. All descriptions of 

the device and its applications, work contexts, details on external testing, information on installation 

and operation are supplied according to our best knowledge. However, this does not mean that the 

characteristics described may entail legal liabilities extending beyond the “General Terms of Sale”, as 

stated in the Pizzato Elettrica general catalogue. Customers/users are not exempt from the obligation 

to examine our information and recommendations, as well as the relevant technical standards, before 

using the products for their own purpose. Taking into account the great variety of applications and 

possible connections of the device, the examples and diagrams given in the present manual are to 

be considered as merely descriptive; the user is deemed responsible for checking that the specific 

application of the device complies with current standards. This document is a translation of the original 

instructions. In case of discrepancy between the present sheet and the original copy, the Italian version 

shall prevail. The present manual may not be reproduced, in whole or in part, without the prior written 

permission by Pizzato Elettrica. All rights reserved

F1B

A4

F1A

CS MP205

A3

+

-

F2B

F2A

axis 1

axis 2

Summary of Contents for CS MP205M0

Page 1: ...to nei limiti d impiego previsti In serie ad ogni uscita di sicurezza a relè installate dei fusibili di valore adeguato al carico solo per versioni con uscite a relè E consigliato alimentare il modulo di sicurezza con una sorgente di alimentazione separata da quella del macchinario e di mantenere separate le connessioni elettriche di potenza da quelle del modulo L alimentazione per questo modulo e...

Page 2: ... Massima resistenza di ingresso 100 Ohm Massima capacita degli ingressi 470 nF verso massa 470 nF tra i due conduttori NB Le tensioni e correnti indicate fanno riferimento ai morsetti di alimentazione Ax vedi caso per caso ogni modulo della scheda dove sono presenti i morsetti di tipo Jx 8 6 Circuiti di ingresso in frequenza Fx Numero ingressi 4 Tensione alimentazione nominale 24 Vdc 15 Tensione e...

Page 3: ...na cava è pari a 180 e l angolo di sfasamento consigliato è pari a 45 Il dente deve comunque garantire la prescrizione che almeno un sensore sia sempre attivo durante la rotazione dell asse Il corretto rilevamento del verso di rotazione di ogni asse deve essere sempre verificato sul macchinario in quanto fortemente condizionato da Accelerazione e velocità angolare dell asse Angolo di sfasamento tr...

Page 4: ...by processors and after power supply they start immediately indicating the relevant input output state When safety module is working without any error in the Normal Operation State the two LEDs P1 P2 of processors are switched off In Normal Operation State the device may intercept some external circuit Malfunctions due to short circuits invalid circuit opening or incorrect status of the inputs see...

Page 5: ...1 Hz Frequency detection accuracy 1 1 digit Resolution 0 1 Hz Minimum detection time closed tree 1 s Galvanic separation Yes Insulation voltage Ui 500 V NB Voltage and current values indicated refer to the power supply terminals Ax see each module individually of the board housing the Fx type terminals 8 7 Testing signal circuits Tx Test signal number 4 Signal type Pulsed 100 Hz 24V 0V duty cycle ...

Page 6: ...ing the rotation of the axes LEDs F1A F1B F2A F2B blink green at the same frequency of the signal received on the proximity sensors inputs The voltage on A3 A4 terminals is correct alternate red green alternate red green alternate red green alternate red green Voltage on A3 A4 terminals is out of the allowed range example terminal detachment sensors failure red red red red Board internal error 14 ...

Reviews: