47
SM53 1053
COM2 serial baud rate (default 57600 baud)
The value that is set defines the
communication velocity of the serial line for
the ModBus protocol, if enabled (baud):
Note: Because the modifications are active, it
is necessary to set this word in the
initialization code. In case no modification is
made or if modifications are made in other
parts of the program, the baud rate will
remain at the default rate set at startup
R/W
0
1
2
3
4
5
110
150
300
600
1200
2400
6
7
8
9
10
11
4800
9600
19200
28800
38400
57600
SM50 1050
EXP1 serial format (default 8, N, 1)
SM54 1054
COM2 serial format (8,N,1 non modifiable)
The value that is set defines the
communications data format of the serial line
for the ModBus protocol, if enabled.
Note: Because the modifications are active, it
is necessary to set this word in the
initialization code. In case no modification is
made or if modifications are made in other
parts of the program, the baud rate will
remain at the default rate set at startup.
R/W
0
1
2
3
4
5
8, N, 1
8, O, 1
8, E, 1
7, N, 1
7, O, 1
7, E, 1
6
7
8
9
10
11
8, N, 2
8, O, 2
8, E, 2
7, N, 2
7, O, 2
7, E, 2
SM51 1051
EXP1 RX/TX delay (default 100 mS)
Summary of Contents for TD240 series
Page 1: ...Manuale operatore...
Page 2: ...2...
Page 6: ...6 3 Mechanical dimensions and installation...
Page 24: ...24 7 1 Starter Kit Connection of the terminal to the PC...
Page 27: ...27 7 2 1 Creation of a new project...
Page 89: ...89 11 Notes Updates...
Page 90: ...90...
Page 91: ...91...