STEADY – During normal operation this light will remain STEADY, indicating that power is on
and the chlorinator is operating correctly.
FLASHING – When FLASHING the monitoring system has detected a water flow problem and
has shut down to prevent damage. It will also be accompanied by a beeping alarm alerting you
of this situation. When problem is rectified normal operation will resume.
STEADY – When this light is illuminated and STEADY it will also be accompanied by a beeping
alarm alerting you of this situation. The chlorinator has overloaded and shut down to prevent
any damage. A direct short between two of the electrode plates coming into contact with
each other could cause this, or a foreign object could be shorting out two or more plates. It
can also be caused by a massively high concentration of salt in the pool water. Depending
on the problem and rectification required, normal operations can proceed. Please note that
the chlorinator power supply must be switched off and then on again to reset the electronic
circuitry and resume operations.
FLASHING – When illuminated and FLASHING the chlorinator is operating correctly in reverse
cycle mode.
SPECIAL NOTE ON WARNING INDICATOR LIGHTS:
When your chlorinator is operating in forward polarity cycle, light number 3 (Fig. 1, item 3)
is on and steady while light number 4 (Fig. 1, item 4) is off.
When your chlorinator is operating in reverse polarity cycle, light number 3 remains on
and steady while light number 4 will flash.
At the end of each cell operational cycle (or cell reverse), the power on/no water flow
light & overload light (Fig. 1, Items 3 & 4) will ALTERNATE by flashing in a slow fashion
for approximately thirty (30) seconds. This is the cell rinse procedure and is part of the
normal operation, which occurs at each reverse cycle change of your Pixie™ reverse
polarity chlorinator. On completion normal operations in the next cycle will begin.
Contrary to popular belief, during both normal and reverse cycle modes the chlorinator
continues to generate chlorine, whilst at the same time the opposite polarity cell plates
are being automatically cleaned.
STEADY
Power on
FLASHING
No Water Flow
STEADY
Cell off
FLASHING
Salt low
SALT HIGHER
THAN NECESSARY
No action required
STEADY
Overload
FLASHING
Normal operation
RP10QTH
RP10TH
STEADY
Power on
FLASHING
No Water Flow
STEADY
Cell off
FLASHING
Salt low
SALT HIGHER
THAN NECESSARY
No action required
STEADY
Overload
FLASHING
Normal operation
STEADY
Power on
FLASHING
No Water Flow
STEADY
Cell off
FLASHING
Salt low
SALT HIGHER
THAN NECESSARY
No action required
STEADY
Overload
FLASHING
Normal operation
RP10QTH
RP10TH
STEADY
Power on
FLASHING
No Water Flow
STEADY
Cell off
FLASHING
Salt low
SALT HIGHER
THAN NECESSARY
No action required
STEADY
Overload
FLASHING
Normal operation