COMMISSIONING
I
I1
ELECTRICAL POWER SUPPLY
I2
WETTING THE PUMP
I3
STATION CONFIGURATION
I4
DISENGAGING THE "MC" SYSTEM
To correctly commission the CUBE MC the sequence of operations indicated below must be
followed and the MC control system functions must be known (see attached manual).
Once the power connections have been made, the CUBE MC can be energised by means of
the master switch to be fitted by the installer on the upstream line. Switching on of the MC
system will be indicated by the lighting up of the two backlit LCDs fitted on the front.
Even when the nozzle is taken out of its seat, the pump WILL NOT start as it has not been
enabled by the MC system.
CUBE MC features a self-priming pump that makes first startup easier. To start the appliance, the
suction pipe need not therefore be completely full of diesel fuel. For quick priming, especially in
the case of installations distinguished by a considerable difference in level between the pump
and the tank, it is however important for the pump to be "wetted", meaning that there must be a
small quantity of diesel fuel inside the impeller chamber.
The pump is supplied adequately "wetted" and ready for use. If however the installer considers
the pump to be totally dry, perhaps due to prolonged storage, he will have to wet it as he thinks
best.
Every CUBE MC station can be adapted to the specific requirements of the station manager.
To do this the MC control system must be CONFIGURED.
After completing configuration, user PIN CODES can be assigned to the persons charged with
using CUBE MC, in accordance with the detailed information in the MC manual.
All the CUBE MC functions are controlled by the MC control system. The MC system can
nevertheless be disengaged for any startup or maintenance activities requiring repeated
pump starting.
In these case, it is often convenient to simplify pump startup by not having to enter any code
and record any dispensing data.
To do this, a JUMPER has been fitted on the card that permits switching from AUTOMATIC
mode (code request to access dispensing) to MANUAL mode (no code request).
EN
15
(Translated from Italian)
MC configuration is crucial and must be done by skilled personnel.
To perform this operation, the MC manual must be carefully and thoroughly read.
! ATTENTION