CUBE • MC
12.4 ELECTRIC CONNECTIONS
ATTENTION
The installation operations are performed with door open and power con-
tacts accessible. All these operations must be performed with the appli-
ance isolated from the power mains to avoid any risk of electric shocks!
All the installation operations must be performed by qualified electro-
technical or electronic staff.
The sections of the cables must be appropriate to the current rates of the
device
Electric connections shall be carried out by specialized personnel in a pro-
fessional way. Full compliance with the regulations in force in the country
where the unit is installed and with the wiring diagrams contained in this
manual is required
ATTENTION
The CUBE MC dispenser does not feature overload cutouts and, conse-
quently, as witch board must be fitted upstream of the CUBE MC complete
with residual current circuit breaker suitable for the type of CUBE MC to
be installed.
CUBE MC features a terminal board cover. Inside this cover are the terminals
which the installer must connect up to:
- The mains power line
- The RS 485 data line to the PC + level indicator (optional).
NOTE
The connector block, accessible through the front panel opening, is already
wired up to the CUBE MC components, according to the block diagram
shown below.
1-
Remove the right termi-
nal board cover.
2-
Connect the cables as
shown in the diagram.
3-
Close the terminal
board cover box again.
7 8
9
10
11
Power 230V
To Motor
OPTIONAL
(RS485 + LEVEL
INDICATOR)
PULSER
K600
NOTE
The parts indicated in the diagram are the only connections to be made by
the customer:
- Connection to power mains.
- RS485 output to PC (OPTIONAL).