M0104 E
36
/64
Installation, use and maintenance
This manual belongs to Piusi S.p.A., which is the sole proprietor of all rights in-
dicated by applicable laws, including, by way of example, laws on copyrights. All
the rights deriving from such laws are reserved to Piusi S.p.A.: the reproduction,
including partial, of this manual, its publication, change, transcription and notifi-
cation to the public, transmission, including using remote communication media,
placing at disposal of the public, distri¬bution, marketing in any form, translation
and/or processing, loan and any other activity reserved by the law to Piusi S.p.A..
4
SAFETY INSTRUCTIONS
Mains - pre-
liminary checks
before instal-
lation
ATTENTION
You must avoid any contact between the electrical power supply and the
fluid that needs to be FILTERED.
Maintenance control
Before any checks or maintenance work are carried out, disconnect the power source.
FIRE AND
EXPLOSION
When flammable
fluids are present
in the work area,
such as gasoline
and windshield
wiper fluid, be
aware that flam-
mable fumes can
ignite or explode.
To help prevent fire and explosion:
Use equipment only in will ventilated area.
Keep work area free of debris, including rags and spilled or open containers
of solvent and gasoline.
Do not plug or unplug power cords or turn lights on or off when flammable
fumes are present.
Ground all equipment in the work area.
Stop operation immediately if static sparking occurs or if you feel a shock. Do
not use equipment until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
ELECTRIC
SHOCK
Electrocution
or death
F
This equipment must be grounded. Improper grounding, setup or usage of the
system can cause electric shock.
Turn off and disconnect power cord before servicing equipment.
Connect only to a grounded electrical outlets.
Use only 3 wire extension cords in accordance with local electrical codes. Ex-
tension cords should have a ground lead.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors.
Never touch the electric plug of socket with wet hands.
Do not turn the dispensing system on if the power connection cord or other im-
portant parts of the apparatus are damaged, such as the inlet outlet plumbing, dis-
pensing nozzle or safety devices. Replace damaged components before operation.
Before each use check that the power connection cord and power plug are not
damaged. If damaged, have power connection cord replaced before use by a
qualified electrician.
The electrical connection between the plug and socket must be kept well away
from water.
Unsuitable extension leads can be hazardous, in accordance with current
regulations. only extension cords that are labelled for outdoor use and have a
sufficient conduction path should be used outdoors.
For safety reasons, we recommend that, in principle, the equipment be used
only with a earth-leakage circuit breaker (max 30 mA).
Electrical connections must use ground fault circuit interrupter (GFCI).
Installation operations are carried out with the box open and accessible elec-
trical contacts. All these operations have to be done with the unit isolated
from the power supply to prevent electrical shock!