Page 7
For technical questions, please call 1-888-866-5797.
Item 63682
S
AFET
y
Op
ERA
TION
M
AINTENAN
c
E
S
ETU
p
Assembly
TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION:
Disconnect the pump from its 12 volt power source before assembly.
Note:
For additional information regarding the parts listed in the following pages,
refer to the Assembly Diagram near the end of this manual.
1. For permanent installation, bolt the
Cover (35) securely to a stable location.
2. Cut the supplied Hose (40) into two lengths.
Make sure that the intake hose is long enough
to reach within one inch of the supply tank
bottom and at the same time long enough
so that the Pump can be located at a point
away from the supply tank opening.
Note:
The included Hose can be cut to provide an
intake hose and an outlet hose, or another hose
of the same size can be purchased as needed.
Any hose used with this product must be
designed for use with the liquid being pumped.
3. Apply pipe thread seal tape (not included) to
the threads of one 3/4" Hose Connector (9)
and screw it firmly into the Pump outlet.
Nozzle (37)
Hose
clamp
(39)
Hose
clamp
(39)
1" Hose
connector
(38)
Outlet
Hose
pump Outlet
3/4" Hose
connector
(9)
Figure B
4. Apply pipe thread seal tape to the threads
of the 1" Hose Connector (38) and
screw it firmly into the Nozzle (37).
5. Slide two Hose Clamps (39) onto the outlet Hose.
Twist one end of the Hose over the Pump outlet
barbed fitting and the other end over the barbed
fitting on the Nozzle. Push the hose forward until the
hose ends press firmly against the fitting shoulders.
6. Slide the Hose Clamps to within 3/8" of the fitting
shoulders and tighten the screws, securing the
Hose onto the fittings. Refer to Figure B.
7. Apply pipe thread seal tape to the threads
of the remaining 3/4" Hose Connector (13)
and screw it firmly into the Pump inlet.
Hose
clamp
(39)
Hose
clamp
(39)
3/4" Hose
connector
(13)
Intake
Hose
Strainer (41)
pump Inlet
Figure c
8. Slide two Hose Clamps (39) onto the intake
Hose. Twist one end of the Hose over the
Pump inlet barbed fitting and the other end
over the barbed fitting on the Strainer (41).
Push the hose forward until the hose ends
press firmly against the fitting shoulders.
9. Slide the Hose Clamps to within 3/8" of the fitting
shoulders and tighten the screws, securing the
Hose onto the fittings. Refer to Figure C.