Troubleshooting
Problem
Possible Causes
Likely Solutions
Decreased output. 1. Not enough air pressure
and/or air flow.
2. Blocked air inlet Filter (3).
3. Air leaking from loose
housing or connections.
4. Mechanism contaminated.
1. Check for loose connections
.
2. Clean air inlet screen of buildup.
3. Make sure housing and connections
are properly assembled and tight.
4. Have qualified technician clean and
where possible, lubricate mechanism.
Severe air leakage.
(Slight air leakage
is normal,
especially on
older tools.)
1. Cross-threaded housing
components.
2. Loose housing.
3. Dirty, worn or damaged valve.
1. Check for incorrect alignment and uneven
gaps. If cross-threaded, disassemble
and replace damaged parts before use.
2. Tighten housing assembly. If housing
cannot be tightened properly, internal
parts may be misaligned.
3. Clean or replace valve assembly.
No output
1. Poor clamp connection.
2. Power Switch in Off
(O) position.
3. Run-down battery.
4. Blown Fuse.
1. Clean clamps and reconnect properly.
2. Turn Power Switch to On (I) position.
3. Recharge battery.
4. Replace Fuse.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect from battery before service.