29
28
DOC_NIP_CON_SMART_EN_20200619
DOC_NIP_CON_SMART_EN_20200619
EN
EN
Soft roller
Measurement
point
Hard roller
Measured value
Measured value
Drive side
Operator side
Rubber thickness
Rubber hardness
Designation
Diameter
Set point
Nr
Tolerance
Designation
Diameter
Fig. 16. Systematic representation of a measurement point and all associated parameters in the
preview window
The (active) roller pairing to be measured can be selected both in the
list and in the roller diagram.
Measured Value Display
Current values and information of the measurement point are displayed and
analysed in the measured value display window.
(
Chapter 7.4.1 General Remarks)
Fig. 17. Measured value display
If the measured value display window is reddish, there is no
connection to the hand-held device.
Measured Values / Set Point Comparison
In addition to the digital display of the current measured values, the result of the
set point comparison is shown in color in the background.
The result of the set point comparison is also visible on the
hand-held device’s optical set point indicators (2).
(
Section 6.2
Operating and Control Elements)
The position of the measured value in relation to the setpoint and
tolerance can also be assessed using the measured value position
indicators.
(
Section 7.4.1 General Remarks)
Set point comparison
Color
Result
Software
Yellow
Measured value too small (out of tolerance)
Green
Measured value (within tolerance)
Red
Measured value too large (out of tolerance)
Hand-held device
Measured value far too small
Measured value too small (out of tolerance)
Measured value (within tolerance)
Measured value too large (out of tolerance)
Measured value far too large
In the event of deviations > 0.5 mm from the tolerance range, the
measured value on the handheld device is marked with "far too
small" or "far too large".
Sensor Position
The external indicators of the
contact position
in the window (as "active sensor
area") realistically shows the contact area of the sensors with the rollers (width of
the indicator bar).
IMPORTANT
If the
critical insertion depth
of the sensors is exceeded, touching
the rollers behind can falsify the measurement (bending errors)
and cause damage.
When critical use of the sensors is recognized, the indicator bar
turns red.