Follow this procedure to check proper operation of the Pitco Self-Cleaning Burner System:

WARNING

Ensure that tank is filled to the level line with oil before turning the

appliance on. Turning the appliance on with an empty or partially filled tank

could cause an unsafe condition, which could lead to damage to the

appliance, property damage or personal injury.

a.  Reconnect the power supply and turn on the gas supply to the appliance.

b.  Energize the unit and check the gas delivery system and Pitco Self-Cleaning Burner System for

gas leaks by applying liquid leak detector or a solution of soapy water to all gas joints and
watching for bubbles at the joints.

c.  If you detect bubbles at any gas joint, turn the appliance off, disconnect the power supply and turn

off the gas supply immediately. Retighten any joints that show signs of leaking and repeat steps a,
b and c until no leakage is detected. If you do not detect any leaks, proceed to step d.

d.  Turn appliance on and observe its behavior. The appliance will execute a Cleaning Cycle every

time it is energized from on “OFF” state, so you may turn the appliance off and then on again to
verify proper execution of the Cleaning Cycle. Refer to the below table to verify proper Cleaning
Cycle execution

Event

Duration

Indication

Turn appliance “ON”

N/A

Control Illuminates, pilot sparks and ignites. Pre-Purge
pulse is initiated.

Pre-Purge Pulse

2 seconds

Appliance operates briefly and stops. Pilot remains lit.

Interwaiting period 1

5 seconds

Appliance does not operate. Pilot remains lit.

Cleaning Pulse

6 seconds

Main valve operates, lighting main burners. SCBS valve
operates, feeding gas to the SCBS Arm. The SCBS arm
ignites, initiating a brief burn at the main burner orifice of
each burner.

Interwaiting period 2

8 seconds

The Main and SCBS valves de-energize for this period.
The pilot remains lit.

Normal operation
resumes

N/A

The appliance operates normally and begins to heat up.
The SCBS Valve remains de-energized until power to
the appliance is recycled. There is no flame on the
SCBS Arm. There is no burn at the main burner orifices.

With the Pitco Self-Cleaning Burner System installed, the appliance should behave as outlined in the above
table. A Cleaning Cycle will execute every time the appliance is turned “ON” from an “OFF” state. The thermal
cut out switch is designed to disable the appliance if the Self Cleaning Burner System malfunctions and
remains activated for an extended period of time or if there is a downdraft into the flue or a blocked flue
situation.

Follow this procedure to adjust and verify proper operation of an appliance using flue baffles
(McDonald’s models MG2 and MG2T):

WARNING

If the appliance you are upgrading is equipped with flue baffles, it may be

necessary to adjust the baffle’s opening to restore proper operation of the

appliance.

If the model you are upgrading is an MG2 or MG2T, it may be necessary to adjust the flue baffle opening to
restore proper operation of the appliance’s combustion system. Flue baffles are used when the appliance is
direct coupled to an exhaust hood, the flue baffle balances the exhaust draw on the combustion system.
When operating properly, the burners should exhibit light blue flame and generate a mild, consistent roar. It is
possible to view the burner flame on the center two burners by peeking sideways into the opening on the air
collars near the pilot. If, during operation the burner flames appear to be lifting or pulsing, the draw of the
hood may be too powerful and the baffle will need to be adjusted to a more restrictive setting. Lifting or
pulsing burners can usually be heard when the

Summary of Contents for L80-029

Page 1: ...on and retain these instructions for the life of the equipment Model __________________________ Serial __________________________ Date Upgraded ___________________ Technician _________________________ Installation Instructions for the PITCO Self Cleaning Burner System E N G L I S H ...

Page 2: ...kit should only be performed by a competent service technician WARNING Do not attempt to move a cooking appliance when the unit is at operating temperature Serious personal injury could result if skin comes in contact with the hot surfaces WARNING DO NOT sit or stand on this appliance Serious injury could result from falling or contact with hot shortening oil WARNING Improper installation alterati...

Page 3: ... face by incinerating any foreign matter that has accumulated from the previous day s operation The Pitco Self Cleaning Burner System is designed to help maintain proper operation and efficiency of your appliance s combustion system by minimizing the build up of any foreign material inside the burner housings Proper installation of this upgrade and periodic maintenance of the appliance are critica...

Page 4: ...onnect the control harness and tuck it out of the way to avoid damaging the harness during this procedure Be sure to store the control in a safe place to avoid accidental damage to it c Using a 7 16 wrench remove the pilot tubing from the gas valve by turning the brass fitting counter clockwise There is no need to remove the pilot from the burner assembly WARNING Ensure that the tank contents have...

Page 5: ...r head WARNING Be sure to keep the removed burners separate from burners supplied with the upgrade kit The existing burners WILL NOT work with the Pitco Self Cleaning Burner System DO NOT attempt to use the old burners with the Pitco Self Cleaning Burner System an unsafe condition may occur g Replace the burners to the LEFT of the pilot with burners supplied with the Pitco Self Cleaning Burner Sys...

Page 6: ...re installed correctly Improperly mounted or poorly aligned burners may result in an unsafe condition or poor appliance performance They should be mounted properly on the orifice fittings facing straight into the burner tubes and secured tightly to the appliance Follow this procedure for installation of the SCBS Valve NOTE The valve type you receive in your kit may differ in appearance slightly fr...

Page 7: ...ng to ensure a gas tight seal NOTE The threads on this fitting 1 8 NPT and compression are not interchangeable Be sure to install the NPT side of this fitting into the gas valve Failure to complete this step correctly could damage the threads of both the fitting and the pressure test port and may result in gas leakage at this joint c Remove the 1 8 NPT X 90 compression fitting from the other end o...

Page 8: ... Reinstall the pilot tubing into the gas valve h Reconnect the control harness to the main gas valve and if you removed a Solid State Control earlier in this procedure you may re install it at this time Follow this procedure to prepare and install the SCBS Control Board and Harnesses a Using a phillips head screwdriver remove the two screws that secure front panel and rotate the control assembly d...

Page 9: ...ined into one single harness NOTE It is critical for proper operation that the insulation paper is installed Failure to install the insulation paper may cause soldered joints on the back of the Control board to short out and damage the Control board and or appliance d Plug four pin connector on SCBS Harness into SCBS Relay Board and ground as shown using the existing fastener to secure ground cabl...

Page 10: ...ws holding the cable retainer plate onto the appliance and remove the cable retainer plate leaving the control cable held in place by the square strain relief Replace the cable retainer plate that you removed with the new one provided in the kit Cable retainer plate style varies from model to model the one that came with your kit should look exactly like the one that you removed with an added hole...

Page 11: ...nt of the appliance Mount the assembly by straddling it on the two burners on either side of the pilot and positioned up to where the flange on the assembly meets with the bottom of the flange on the burner web see photos at right l Fasten the Thermal Limit Switch to the flange on the burner web using two self drilling fasteners provided in the Pitco Self Cleaning Burner System Kit Connect the lea...

Page 12: ... at the main burner orifice of each burner Interwaiting period 2 8 seconds The Main and SCBS valves de energize for this period The pilot remains lit Normal operation resumes N A The appliance operates normally and begins to heat up The SCBS Valve remains de energized until power to the appliance is recycled There is no flame on the SCBS Arm There is no burn at the main burner orifices With the Pi...

Page 13: ... these instructions If there appears to be significant roll out during ignition or any time during operation proceed to step d of this section of these instructions c For pulsing lifting burner flame Turn the appliance off and allow it to cool Pull the appliance out from under the hood and loosen the screws securing the adjustable slide plate on the flue baffle Move the slide plate toward the rear...

Page 14: ...ation Refer to flue baffle adjustment procedure in these instructions to set flue baffle to a less restrictive setting Model MG2 or MG2T flue baffle is set too restrictively Faulty hi limit switch Appliance will not maintain temperature properly Refer to Service and Parts manual to diagnose this problem and replace temperature probe Refer to Service and Parts manual to diagnose this problem and re...

Page 15: ...13 L80 029 Rev 5 10 07 ...

Page 16: ...L80 029 Rev 5 10 07 14 ...

Page 17: ...15 L80 029 Rev 5 10 07 ...

Page 18: ...L80 029 Rev 5 10 07 16 ...

Page 19: ...17 L80 029 Rev 5 10 07 ...

Page 20: ...L80 029 Rev 5 10 07 18 ...

Page 21: ...19 L80 029 Rev 5 10 07 ...

Page 22: ...L80 029 Rev 5 10 07 20 ...

Page 23: ... the installation of the SCBS upgrade Wire harnesses and pilot tubing are omitted to provide better clarity In order to give the installer a sense of part orientation and location the gas piping parts valve tubing runner arm and fittings of the SCBS system are shaded For clarity the thermal limit switch assembly is not shaded ...

Page 24: ... about your order please contact the Pitco Frialator factory at 800 258 3708 US and Canada only or 603 225 6684 World Wide In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the numbers listed to the left ...

Reviews: