background image

Spin Fryer I12 Cooking Computer 

Pitco P/N 60149505 

 

Page 23 of 28 

L22-355 Rev 1 

6 Other 

Displays: 

 

Open probe detection is standard on all Pitco 
controls.  If probe is detected open, normal 
heating and cooking activities are suspended. 

 

This display warns operators that the vat 
temperature has exceeded set temperature by 
+40°F (+22°C), or an absolute maximum of 
410°F (210°C). The alarm will also sound.  This 
display does not show the status of the 
mechanical high limit switch.  

 

This message indicates that the drain valve has 
been opened, the vat is assumed to be empty by 
the controller.  Normal heat control activities are 
suspended.  Display will show an alternating 
message [DRAINING] / [TURN OFF]. To restore 
to normal operation, close the drain value.  
Display will show [TURN OFF]. 

Turn controller off, and refill the vat.  Continue 
with normal operations at section 1. 

 

 

This message indicates that the heating system 
failed to respond.  Typically, the high 
temperature limit switch has tripped and is in 
need of resetting.  In the case on gas fired 
appliances, this message will display if the pilot 
fails to light or is detected marginal by the 
ignition module. Display will show an alternating 
message [HEAT] / [FAILURE]. 

 

 

This message indicates a shorted probe. If probe 
is detected as a short circuit, normal heating and 
cooking activities are suspended. Display will 
show an alternating message                   
[SYSTEM] / [FAILURE]. 

 

 

This message indicates that a recoverable 
system error has occurred. Press ‘6’ for YES to 
perform a factory reset or ‘0’ for NO to return to 
OFF. Normal use of the system will only resume 
when a factory reset has been performed. 
Display will show an alternating message                   
[FACTORY] / [RESET]. 

 

Summary of Contents for L22-355

Page 1: ...rogrammed with cook shake and hold times to keep pace with changing menus over time This manual details the operation and adjustment of the Spin Fryer I12 Cooking Computer control The target audience...

Page 2: ...ager 10 3 1 Fahrenheit or Celsius Display ___________________________________________________ 10 3 2 Password Change or Required _________________________________________________ 10 3 3 Beeper ON OFF...

Page 3: ..._______ 20 5 7 Ready Level _________________________________________________________________ 20 5 8 Operating Temperature Range___________________________________________________ 20 5 9 High Limit Val...

Page 4: ...isplays Wait for the appliance to heat up to the READY condition before cooking 1 2 To turn the appliance OFF Press the key Display will momentarily show the software version number and then 1 3 To st...

Page 5: ...show CKn mm ss followed by SHn mm ss then HDn mm ss ending with PA4 mm ss Where n is the key number and mm ss is the time setting After a few moments the display will return to or or CKn mm ss for any...

Page 6: ...pt Pressing the 0 key is a YES response to the boil prompt If pressed display will show Heat will maintain vat temperature at 185 F 85 C for cleaning as long as the control remains on To exit boil mod...

Page 7: ...one of the following displays or Press the key If display shows a password is required Enter password Level 1 2Password 6 8 6 4 using the product keys as a numeric keypad for entry With correct passwo...

Page 8: ...alue is zero meaning the Shake Time is inactive To use Shake Time the time value must be a non zero value and must be set to a value less than cook time Display shows nSH mm ss TIME where n is the key...

Page 9: ...ill not spin after a cook cycle if the set spin time is set to 0 Display shows nST mm ss TIME where n is the key number ST means Spin Time and mm ss is minutes and seconds Use the product keys for num...

Page 10: ...Display shows Press product key 1 display shows DEGREE n F OR C where n is the current setting Use the product key 0 to scroll through choices F or C Press key to save choice Display shows 3 2 Passwo...

Page 11: ...ow Press product key 4 display shows ENGLISH LANGUAGE Use the product key 0 to scroll through choices ENGLISH ESPANOL FRANCAIS DEUTSCH HOLLAND Press key to save choice Display shows 3 5 Melt Cycle Typ...

Page 12: ...increased recovery times stored in this display There is no selection done here just the display of recovery time values With display showing press the product key 0 Display will show Press product k...

Page 13: ...the probe temperature With display showing press product key 1 Display shows OFF nn F DEGREES where nn is the value of the adjustment Negative values are preceded with a minus sign To change this val...

Page 14: ...Use the product keys for numeric entry of a new value Press the key Display now shows 3 4 4 Recovery Times This controller maintains a record of heat up times for the appliance A poorly running appli...

Page 15: ...ake Toggles basket lift brake output on and off Display will show Brake Brake 2 4 5 3 Heat Demand Output Hold the product key 3 to force Heat Demand output ON Display will show HEAT DEM Releasing the...

Page 16: ...380 No adjustments are permitted here This is an information display only Press the key Display returns to 7 4 8 More Service Menu Entry With display showing press product key 8 to enter submenu Displ...

Page 17: ...lue then press the to save choice Display returns to 4 8 4 Hold Alarm Duration With the display showing press product key 5 Display will show HD DUR nn DURATION where nn is the time in seconds the hol...

Page 18: ...is off Note Heat Demand Profile section 4 8 3 must be set to Generic 1 or T stat Standing Pilot toggle has no effect in with any other setting With the display showing press product key 9 Display will...

Page 19: ...wing press product key L Display shows PCOLLECT OFF This toggle forces the RS 485 link to output data collection parameters during test and calibration This has no meaningful use in the field Note Do...

Page 20: ...xcept is displayed instead of SERVICE 5 8 Operating Temperature Range This menu is identical to Temperature Operating Range section 4 7 except is displayed instead of SERVICE 5 9 High Limit Value With...

Page 21: ...aximum of 500 RPM 1 5 10 3 Motor Speed Decrease Decreases the spin motor s speed in 10 RPM increments up to a minimum of 60 RPM 2 5 10 4 Spin Direction Toggles the motor s spin direction from spinning...

Page 22: ...ntrol ID Display From the display press the 0 key Display will show CONTROL 60149505 the Pitco part number 60149505 Press the 0 key again Display will show S W 0149501x this is Pitco s software number...

Page 23: ...value Display will show TURN OFF Turn controller off and refill the vat Continue with normal operations at section 1 This message indicates that the heating system failed to respond Typically the hig...

Page 24: ...ransformer Display will show an alternating message SM_POSIT FAILURE This message indicates that the basket lift was unable to detect the target position during operational basket lift movement Basket...

Page 25: ...Spin Fryer I12 Cooking Computer Pitco P N 6049505 L22 280 Rev 1 25 of 28 7 Mechanical Dimensions...

Page 26: ...N PWR 24VACN 24VAC Return 3 PROBE 4 PROBE 5 DVI IN 24VAC Drain Valve Interlock 6 HFB IN 24VAC Heat Feed Back 7 24VDC COM IN 24VDC DC Returm 8 HD OUT 24VDC Heat Demand 9 SO xFER OUT 24VDC Side ON or XF...

Page 27: ...96 65 18 3 122489 230 110 0 4675 395 201 7 576 09 70 21 1 108051 235 112 8 4329 400 204 4 547 09 75 23 9 95539 240 115 6 4013 405 207 2 519 86 80 26 7 84644 245 118 3 3723 410 210 0 494 24 85 29 4 75...

Page 28: ...lator factory at 603 225 6684 World Wide www pitco com In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative AS...

Reviews: