PITCO Frialator, Inc.
P.O. Box 501, Concord, New Hampshire 03301
1
1
2
2
3
3
4
4
1
1
1
1
4
4
1
1
Howling or screeching noise
when burners are on.
Main burner flames are
yellow.
SECTION 2S TROUBLESHOOTING CHART
Gas pressure too high.
Adjust pressure regulator.
Loosen burner mounting
screws and line up burners.
2
3
Burner flames will not enter
heat tubes.
Dirt or burr on burner orifice.
Clean orifice or replace.
Defective Unitrol.
Clogged vent cap on Unitrol.
Orifices are too large.
2
Main burners dirty.
Improper gas pressure.
TROUBLE
POSSIBLE CAUSE
REMEDY
Improper air collar adjustment
Main burners will not shut
off automatically.
2
2
Replace Unitrol.
Remove and clean cap.
2
Call factory to learn proper
sizes.
Remove burners and clean.
On natural gas adjust Unitrol
pressure regulator to 4.0" w.c
operating pressure. On
propane gas have gas supplier
adjust tank pressure to provide
10.0" w.c. operating pressure
at the fryer. (See Orifice and
Burner pressure chart)
3
Gas pressure too high/low.
Burners out of alignment.
a. Turn Vent on.
Orifices may be incorrect size.
Call factory to learn proper
sizes.
Protect flue opening from
downdrafts, breezes or air
flows from blowers.
Downdraft on fryer flue
opening, or vent not turned on.
Remove and clean cap.
On natural gas adjust Unitrol
pressure regulator to 4.0" w.c
operating pressure. On
propane gas have gas supplier
adjust tank pressure to provide
10.0" w.c. operating pressure
at the fryer. (See Orifice and
Burner pressure chart)
2
Summary of Contents for 14R
Page 5: ......
Page 9: ...NOTES...
Page 10: ...SECTION 3S PARTS LIST MODEL 14R 18 WKS...
Page 13: ...NOTES...
Page 15: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...
Page 16: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...
Page 18: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...
Page 19: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...
Page 20: ...L20 310 R1 02 15...