TO REMOVE MAIN BURNER

a. Turn Unitrol knob to “OFF" position.

b. Loosen set screw in base of burner casting.

c. Unscrew and remove two hex head screws at top of burner.

d. Unscrew and remove air collar from burner.

e. Lift burner up to clear top of burner fitting and remove from fryer.

f.

Reverse procedure to remount burner.

1.2 

TO CHANGE MAIN BURNER ORIFICE

a. Follow procedure in Section 1.1.

b. After burner has been removed, unscrew orifice with 3/8” wrench.

c. Screw in new orifice – tighten gas tight.

d. Remount burner and air collar.

1.3 

TO REPLACE HEAT TUBE BAFFLES

a. Remove main burners: follow procedure in Section 1.1.a. through e.

b. Baffles are fastened to the inside of the heat tube by a small tack weld on the right

hand front baffle support. Break leg away from weld with a chisel or solid steel bar.

c. Remove old baffles and insert new ones in tubes in original position.

d. Remount main burners.

1.4 

TO REMOVE PILOT BURNER

a. Follow procedure in Section 1.1 and remove main burner to the right of the pilot

burner.

b. Unscrew and remove tubing nut from pilot tubing connection on Unitrol.

c. Unscrew and remove thermopile or thermocouple from connection on Unitrol.

d. Unscrew and remove the two screws holding the pilot to the bracket on the fry tank

and lift the entire pilot assembly out of the fryer.

1.5 

TO CHANGE PILOT BURNER ORIFICE

a. Follow procedure in 1.4.

b. Unscrew tubing nut in fitting in base of pilot burner.

c. Unscrew fitting in the base of pilot burner and withdraw orifice from inside the fitting.

d. Insert new orifice and reverse procedure to re-assemble.

e. Tighten all screws and connections and test for gas leaks.

Summary of Contents for 14R

Page 1: ...INC P O BOX 501 CONCORD N H 03301 PHONE 603 225 6684 SERVICE DEPT 603 225 5688 L20 310 R1 02 15 TROUBLESHOOTING MANUAL IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this m...

Page 2: ...cedures Burner Flow Drawing Section 2S Troubleshooting Charts Section 3S Parts List Section 4S Front Panel Bezel Orifice Tips Burner Pressure Section 5S Entrance Box L20 310 R0 02 15 SERVICE MANUAL 14...

Page 3: ...s are fastened to the inside of the heat tube by a small tack weld on the right hand front baffle support Break leg away from weld with a chisel or solid steel bar c Remove old baffles and insert new...

Page 4: ...ned f Replace pilot orifice if desired flame cannot be obtained by adjustment See procedure 1 5 1 8 TO REPLACE LIMIT CONTROL a Turn Unitrol knob to OFF b Drain all shortening from fry tank Remove tube...

Page 5: ......

Page 6: ...ing should be between 25 and 35 mv for thermocouple 5 SECTION 2S TROUBLESHOOTING CHART Thermopile or thermocouple producing insufficient millivoltage 3 3 Pilot will light but Unitrol pilot gas valve w...

Page 7: ...but burners will not light Pilot flame and main burners cut off while cooking 2 2 Pilot will light but Unitrol pilot gas valve will not hold open automatically Float switch bulb off or stuck down Inst...

Page 8: ...place Unitrol Remove and clean cap 2 Call factory to learn proper sizes Remove burners and clean On natural gas adjust Unitrol pressure regulator to 4 0 w c operating pressure On propane gas have gas...

Page 9: ...NOTES...

Page 10: ...SECTION 3S PARTS LIST MODEL 14R 18 WKS...

Page 11: ...P6071353 Burner Orifices Propane 18 See Orifice Chart See Section 3S Burner Orifices chart CE 12 A8001001 Air Collar 14 A8001101 Burner Fittings 15 B8005601 Manifold 17 PP10025 Main Burner Bolt 18 PP...

Page 12: ...P 50 No 1 32 I3B P 50 No 1 25 GAS CATEGORY ORIFICE TIP SIZE mm GAS CATEGORY Supply Pressure mbars Governor on Gas Valve ORIFICE TIP SIZE mm I2H I2E I2E I2ESI 2 38 I3P 50 No 1 15 I2L 2 58 I3P 37 No 1 2...

Page 13: ...NOTES...

Page 14: ...Schematic 700131 Schematic 2 DS2 P5045044 Lamp S2 PP10093 Switch On Off S3 PP10559 Switch Start On Off DVI drain switch 4 K2 PP11124 Relay 24V SPDT DC 10 K3 P5046686 Relay 24V DPDT AC B6711702 Harness...

Page 15: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...

Page 16: ...SECTION 4S FRONT PANEL BEZEL SCHEMATIC MODEL 14R 18 WKS...

Page 17: ...115V B2904504 Entrance Box 220 240V 1 P5045794 Fuseholder PP10122 1 Amp Fuse 115V P5045717 2 Amp Fuse 220 240V 1 P5045794 Fuseholder 1 PP10122 1 Amp Fuse 115V 4 1 PP10210 40VA Transformer B6713901 Wir...

Page 18: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...

Page 19: ...SECTION 5S ENTRANCE BOX ASSEMBLY MODEL 14R 18 WKS ENTRANCE BOX SCHEMATIC OF 700131...

Page 20: ...L20 310 R1 02 15...

Reviews: