ENGLISH
22
9. Perform a leak test and check burner operation after re-assembly.
10. Replace flavor activator and cooking grid.
EMERGENCIES
Problem
Possible Cause
Solution
Gas leaking from LP
Gas Cylinder.
Mechanical failure
due to rust or
mishandling.
Replace LP Gas Cylinder.
Gas leaking between
LP Gas Cylinder
and regulator
connection.
Improper installation,
connection not tight,
failure of seal on LP
Gas Cylinder.
Remove LP Gas Cylinder. Re-install
correctly and tighten. Replace
Cylinder if damaged. See "Leak
Test" and "Connecting Regulator
to LP Gas Cylinder" sections.
Grease fire or
excessive flames
above cooking
surface.
To much grease
build-up in burner
section.
Turn off Regulator Knob and
remove LP Gas Cylinder. Once
fire is out and grill has cooled off,
clean residual food particles and
excess grease from inside firebox
area, grease cup, and other
surfaces.
Flashback
(Fire in or
around Venturi tubes).
Clogged or blocked
Venturi tube.
If you can safely reach the
Regulator Knob, turn it to the
"Off" position, then remove the
LP Gas Cylinder. Once grill has
cooled, clean burner and Venturi
tubes. See "How to Clean Burners"
section.