■ Order Example
■
Manifold type (VKM)
Example
.When all stations have common specifications.
VK M H 10 W – T6 20 S2 E – B 04 – NW
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
①
Port orientation
:
M
→
Manifold
②
Vacuum characteristics
:
H
→
High-vacuum type
③
Nozzle bore
:
10
→
ø1.0mm
④
Combinations
:
W
→
Filter, Suction solenoid valve, Vacuum switch with LED display and Blow-off solenoid
valve
⑤
Vacuum port
:
T6
→
ø6mm Push-In Fitting on top
⑥
Air supply port
:
20
→
ø10mm Push-In Fittings on both sides of manifold
⑦
Exhaust port
:
S2
→
Silencers on both sides of manifold
⑧
Solenoid valve type
:
E
→
Normally closed (N.C) type 24VDC
⑨
Color
:
B
→
Black
⑩
N
umber
of stations
:
04
→
4 stations
⑪
Switch output
:
NW
→
NPN open collector output with 2 switch output
■
Manifold installation top-mounting unit alone
Example
.When vacuum port is installed on the side of the manifold-base.
VK M H 07 G – 00 00 00 E – W
①
②
③
④
⑤
⑥
⑦
⑧
⑨
①
Port orientation
:
M
→
Manifold type
②
Vacuum characteristics
:
H
→
High-vacuum type
③
Nozzle bore
:
07
→
ø0.7mm
④
Combinations
:
G
→
Filter and Suction solenoid valve
⑤
Vacuum port
:
00
→
Applicable to installation on the side (front) of a manifold
⑥
Air supply port
:
00
→
Applicable to a manifold installation top-mounting unit alone
⑦
Exhaust port
:
00
→
Applicable to a manifold installation top-mounting unit alone
⑧
Solenoid valve type
:
E
→
"Normally Closed" (N.C.) type 24VDC (for both suction and blow-off)
⑨
Color
:
W
→
Light-gray
Example
.When vacuum port is installed on the upper plane of the station
VK M H 12 R – T
1/4
00 00 E – W – NA
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑪
①
Port orientation
:
M
→
Manifold
②
Vacuum characteristics
:
H
→
High-vacuum type
③
Nozzle bore
:
12
→
ø1.2mm
④
Combinations
:
R
→
Filter, Suction solenoid valve, Vacuum switch with LED display and Air timer type blow-off valve
⑤
Vacuum port
:
T
1/4
→
ø
1/4"
Push-In Fitting on top
⑥
Air supply port
:
00
→
Applicable to a manifold installation top-mounting unit alone
⑦
Exhaust port
:
00
→
Applicable to a manifold installation top-mounting unit alone
⑧
Solenoid valve type
:
E
→
" Normally closed" (N.C.) type 24VDC (for both suction and blow-off)
⑨
Color
:
W
→
Light-gray
⑪
Vacuum switch
:
NA
→
NPN open collector switch output and analog output
Note) For manifold installation top-mounting unit, vacuum ports are provided with a seal packing and two threads.
(Seals are not provided for exhaust port and supply port.
→
Instead, they are attached to manifolds)