VKB
11
17
19
16
18
36
3.8
73
19
2-ø3.2
10 25
29.5
3.5
8
EXH V
P
Unit connecting thread
(thread part to fix manifold)
Side port surface
for manifold type
Mounting unit for manifold
VKB
□□□
B……
(Combination code: B type,
Vacuum generator, Filter and
Check valve.)
VKB
□□□
A……
(Combination code: A type,
Vacuum generator and Filter.)
Vacuum release air
needs to be supplied
from outside when
separating a work.
←
VKB
EXH V P
33
44
19 17
16
18
36
3.8
106
52
10
58
11 500
2-ø3.2
3.5
29.5
8
Unit connecting thread
(thread part to fix manifold)
Side port surface for manifold type
Mounting unit for manifold
Mechanical vacuum switch
Black
:
N.O
Red
:
N.C
White
:
Com
VKB
□□□
C……
(Combination code: C type,
Vacuum generator, Filter and
Mechanical vacuum switch.)
VKB
□□□
D……
(Combination code: D type, Vacuum
generator, Filter, Check valve,
Mechanical vacuum switch.)
(Mechanical type)
(Mechanical type)
Vacuum release air
needs to be supplied
from outside when
separating a work.
←
A-B Type
C-D Type
VKB
112.5
Operation indicator LED
LED display
10
64.5
500
66
39.5
50.5
19 17
2-ø3.2
3.5
29.5
16
23.8
41.5
3.8
58.5
8
EXH V P
Unit connecting thread (thread part to fix manifold)
Side port surface for manifold type
Vacuum switch
with LED display
Mounting unit for manifold
kPa
SW2
SW1
S1 S2
ME
MODE
VKB
□□□
F……
(Combination code: F type, Vacuum
generator, Filter, Check valve,
Vacuum switch with LED display.)
VKB
□□□
E……
(Combination code: E type,
Vacuum generator, Filter and
Vacuum switch with LED display.)
(Digital type)
Vacuum release air
needs to be supplied
from outside when
separating a work.
←
(Digital type)
E-F Type
Circuit diagram
Circuit diagram
Circuit diagram
Model code
VKB
□□□
A
……
VKB
□□□
B
……
Model code
VKB
□□□
C
……
VKB
□□□
D
……
Model code
VKB
□□□
E
……
VKB
□□□
F
……
http://www.pisco.com