8.

 

INSTALLATION 

Only  skilled  and  authorised  technicians  can  install  and  connect  the  stove  verifying  that  it  functions  properly,  in  compliance 
with  current  regulations  and  assembling  instructions.

PiQuadro  A+3s.r.l.  declines  any  responsibility  for  damages  to  objects 

and/or persons caused by improper installation. 

 

8.1

 

INSTALLATION REQUIREMENTS

 

Before installing the stove carefully read the following instructions. More specifically:  
 

 

Connect it to the flue for fume exhaustion.

 

 

Connect it to your power supply system.

 

 

Connect it to your heating system. 

 

 

Connections must be compliant with current regulations; PiQuadro A+3 s.r.l. declines any responsibility for 
damages caused by improper connections and systems.

 

 

8.2

 

POSITIONING OF THE STOVE

 

-

 

Position the stove so that the plug is easily accessible. 

-

 

In order to ensure a good functioning and an even distribution of temperature, leave adequate clearance and air for the 
pellets to burn, in compliance with installation instructions and national regulations. 

-

 

Air will flow through the permanent inlets on the outside walls of the stove. 

-

 

Position the stove far from inflammable objects such as wooden furniture, curtains and sofas. 

-

 

If the stove is to be supported by a wooden floor, use a floor-protection plate in compliance with national regulations. 

-

 

Make  sure  that  the  room  can  provide  at  least  as  much  air  as  required  by  the  device  normal  burning  and  by  room 
ventilation. 

-

 

For your own safety and comfort, please make sure that the room has a suitable air scoop. (UNI10683) 

-

 

Do not install the stove in bedrooms or bathrooms. 

-

 

The  stove  cannot  be  installed  in  the  same  room  whit  another  heating  device  if  two  independent  air  pipes  are  not 
available. 

-

 

Do not position the stove in explosive environments. 

-

 

Check that the floor can support the total weight of the stove. 
For a correct positing of the stove follow the instructions below: 

-

 

Put  the  stove  on  the  floor  in  a  place  where  it  can  be  easily  connected  to  the  flue  and  to  the  exhausting  and  thermal 
system. 

-

 

Connect  the  flue  checking  that  the  fume  exhaustion  outlet,  on  the  back  or  on  the  right  side  of  the  stove,  is  positioned 
correctly. 

 
 
MEASURES FOR REAR FUME EXHAUSTION PIPE CONNECTION (Figure 4) 

f1 =  215 mm 
e1 = 80 mm 
Diameter = 80 mm 
 

MEASURES FOR SIDE FUME EXHAUSTION PIPE CONNECTION (Figure 5) 

f2 = 215 mm 
e2 = 95 mm 
Diametre = 80 mm 

FIG 5 

 

FIG 4

 

 

 

 

 

 

FIG 5 

 

 

 

 

 

Summary of Contents for CARBONARA CAR80D

Page 1: ...PELLET STOVE CARBONARA OPERATING INST PELLET STOVE CARBONARA OPERATING INSTALLATION AND MAINTENANCE MANUAL MOD CAR80D CARBONARA ALLATION AND MAINTENANCE MANUAL...

Page 2: ...7 3 VISUAL MATCH OF THE STOVE 7 8 INSTALLATION 8 8 1 INSTALLATION REQUIREMENTS 8 8 2 POSITIONING OF THE STOVE 8 8 3 SAFELY CONNECT OPERATE THE STOVE 9 8 4 EXTERNAL AIR INTAKE AND CONNECTION TO THE FL...

Page 3: ...PERATURE REACHES SET ROOM TEMPERATURE 20 12 21 CLEANING THE BRAZIER 20 12 22 SWITCHING THE STOVE OFF 20 12 23 SWITCHING THE STOVE ON AGAIN 20 13 WHAT IF THE PELLET DOES NOT IGNITE 21 13 1 THERE IS A P...

Page 4: ...ile it is operating The above described intended use of the stove and the relative configurations are the only ones permitted by the manufacturer never use the stove in ways not described in the provi...

Page 5: ...ation must be carried out by qualified and authorized technicians Laws regulations and directives relating to chimney configuration ventilation exhaustion power supply and other systems must be respec...

Page 6: ...xhaustion outlet C Air louvers P Air duct door D Combustion chamber fire box Q Door handle hook E Pellets outlet channel R Alternative hot air outlet F Brazier S Toxic air inlet G Spark plug T Adjusta...

Page 7: ...pliant with UNI EN 14785 2006 Pellets with the following features are recommended Type of pellet VIRGIN WOOD Diameter 6 mm Average length 15 20 mm Moisture 8 Heating power Max 4 500 Kcal Kg Power Weig...

Page 8: ...anent inlets on the outside walls of the stove Position the stove far from inflammable objects such as wooden furniture curtains and sofas If the stove is to be supported by a wooden floor use a floor...

Page 9: ...ted for your children s safety For your own safety and comfort please make sure that the room has a suitable air scoop UNI10683 For the good functioning of the stove leave adequate clearance and air f...

Page 10: ...must have a positive gradient of no less than 3 in horizontal pipes The overall length shall not be more than 2 m whereas in vertical pipes between a T fitting and other fittings change of directions...

Page 11: ...uring packaging Make sure there is nothing left inside the tank 9 1 FUEL CHARGE When loading the fuel make sure the bag containing the pellets doesn t touch the stove The fuel has to be loaded in the...

Page 12: ...rning residues Reposition the flame retardant plate and the ash pan Reposition the ash pan making sure that the bigger hole on its right side its with the ignition resistance pipe Close the fire box d...

Page 13: ...xtraordinary cleaning Warning for extraordinary maintenance please refer to section Brazier F Ash pan I Flame trap M Brazier support H Flame retardant plate L Inspection plug Fumes M1 11 CONTROL PANEL...

Page 14: ...hrono 01 enable chrono 01 enable chrono On off 02 daily prog 01 daily chrono On off 02 02 start day 1 Hour 03 stop day 1 Hour 04 start day 2 Hour 05 stop day 2 Hour 03 weekly prog 01 weekly chrono On...

Page 15: ...Wednesday prog 2 34 Thursday prog 2 35 Friday prog 2 36 Saturday prog 2 37 Sunday prog 2 end programming 01 week end chrono 02 start 1 03 stop 1 04 start 2 05 stop 2 SET TIME AND DATE Set the current...

Page 16: ...evious settings Daily weekly week end programming 02 DAILY PROGRAMMING Allows you to enable disable and set daily chrono thermostat functions Two slots can be set based on 2 ignition and 2 off operati...

Page 17: ...le programming options The weekly programming can be enabled and disabled as shown in the graphic Moreover by selecting OFF in the hour filed the clock ignores the corresponding command Attention Care...

Page 18: ...2 On off 03 03 16 Thursday Prog 2 On off 03 03 17 Friday Prog 2 On off 03 03 18 Saturday Prog 2 On off 03 03 19 Sunday Prog 2 On off Program 3 Menu level Selection Meaning Possible values 03 03 20 Sta...

Page 19: ...stove enable one programming option at a time MENU 04 CHOOSE LANGUAGE Allows you to choose the language you prefer among the available ones BY MODE BY mode which shuts down the stove when the room tem...

Page 20: ...lly brought down to minimum value called MODULATION If the STAND BY mode is activated the stove starts to working again until Pr13 value is reached Restart is possible when the above conditions are fu...

Page 21: ...set by Pr11 Press P4 to stop it 13 2 FUME PROBE ALARM The alarm will go off if the fume probe is broken or disconnected During the alarm the stove shuts down automatically 13 3 HOT TEMP ALARM It occu...

Page 22: ...ropriate safety devices e g anti perforation gloves when carrying out maintenance operations Carry out maintenance when the stove is shut down and completely cooled off 14 1 OPERATIONS TO BE CARRIED O...

Page 23: ...area subject to anomalous environmental conditions or if damages occur because of atmospheric agents or because of climate chemical or electrochemical factors The warranty is not valid if bad function...

Page 24: ...Operating installation and maintenance manual CARBONARA CAR80D 24...

Page 25: ...the purchase date N B The form is either registered or sent back to the purchaser The latter needs to save the warranty certificate and the fiscal receipt showing the purchase date I hereby authorise...

Page 26: ...Operating installation and maintenance manual CARBONARA CAR80D 26 Via Papa Giovanni XXIII 61045 PERGOLA PU ITALY T 39 0721 736733 F 39 0721 739315 www piquadrocalore com service piquadrocalore com...

Reviews: