Operating, installation and maintenance manual CARBONARA - CAR80D
20
12.16
OPERATING STOVE
After having been successfully switched on, the stove shifts to normal working phase. If the fume temperature is higher than
Pr15, heat exchangers are automatically activated.
12.17
SETTING ROOM TEMPERATURE AND POWER
To set room temperature, select the CHANGE TEMP SET by pressing P2 key. Use P1 and P2 keys. The display shows the status of
the current temperature SET. To set power select the CHANGE POWER SET by pressing P6 key. Use P6 and P5 keys. The display
shows the status of the current power SET.
12.18
USE OF THERMOSTAT/EXTERNAL CHRONO-THERMOSTAT
You can use an external thermostat. We strongly suggest that you contact a qualified technician for installation.
•
Thermostat: program a temperature SET of 7°C
•
External chrono-thermostat: program a temperature SET of 7°C and disable the chrono functions in the menu.
12.19
WHEN THE ROOM TEMPERATURE HAS REACHED THE SET VALUE
When the room temperature has reached the set value, or the fume temperature gets to Pr13, the heat power is automatically
brought down to minimum value, called MODULATION. If the STAND-BY mode is activated, the stove starts to working again until
Pr13 value is reached. Restart is possible when the above conditions are fulfilled.
12.20
RESTART AFTER SWITCHING OFF
WHEN TEMPERATURE REACHES SET ROOM TEMPERATURE
After the STAND-BY switching off, the stove cools down and the fume exhaustion speed is brought to maximum level. After the
switching off, the stove cools down and the exhaustion speed is brought to the level determined by Pr29. Restart is possible once
the following condition is fulfilled:
Room T < (T set - Pr43)
12.21
CLEANING THE BRAZIER
In normal working conditions and at intervals set by Pr03, the CLEANING BRAZIER mode is activated for a period of time
determined by P12.
12.22
SWITCHING THE STOVE OFF
Simply press P4 key for 2 seconds to shut the stove down. The auger is immediately blocked and the fume exhaustion system is
brought to a high speed working mode. A FINAL CLEANING phase is thus carried out. The fume exhaustion stops after a time set
by Pr39, after the fume temperature drops below the value determined by Pr13.
12.23
SWITCHING THE STOVE ON AGAIN
You cannot restart the stove until the fume temperature is under P13 value and the safety time determined by Pr38 has elapsed.