background image

 

 

 

 

 

 

 

 

 

 

PELLET STOVE:

 

BRUSCHETTA

 

 

 

OPERATING, INSTALLATION AND MAINTENANCE MANUAL

 

MOD. BRU70D - BRU70M

 

Summary of Contents for BRUSCHETTA BRU70D

Page 1: ...PELLET STOVE BRUSCHETTA OPERATING INSTALLATION AND MAINTENANCE MANUAL MOD BRU70D BRU70M...

Page 2: ...STOVE 7 8 INSTALLATION 8 8 1 INSTALLATION REQUIREMENTS 8 8 2 POSITIONING OF THE STOVE 8 8 3 SAFELY CONNECT OPERATE THE STOVE 9 8 4 EXTERNAL AIR INTAKE AND CONNECTION TO THE FLUE 9 8 5 CONNECTION TO A...

Page 3: ...Operating installation and maintenance manual BRUSCHETTA BRU70D BRU70M 3 16 RECOMMENDATIONS FOR TECHNICIANS 18 17 WARRANTY CONDITIONS AND CLAIMS 19 18 WARRANTY CERTIFICATE PiQuadro A 3 S r l 21...

Page 4: ...sons with limited physical sensory or mental capacities or with insufficient experience or knowledge The appliance is not intended for use by children Make sure children do not get close to the stove...

Page 5: ...ng parts please contact your area manager your retailer or the manufacturer 6 SAFETY INFORMATION 6 1 RECOMMENDATIONS FOR THE TECHNICIAN Comply with the requirements hereafter specified Installation mu...

Page 6: ...and designed especially for this purpose The stove main parts and contro M Pellet tank lid chamber door handle N Fume exhaustion outlet O Inlet for power supply 220 volt Combustion chamber fire box P...

Page 7: ...30x458x540 830x458x540 7 2 FUEL TYPE AND QUANTITY Use fuel compliant with UNI EN 14785 2006 Pellets with the following features are recommended Type of pellet VIRGIN WOOD Diameter 6 mm Average length...

Page 8: ...national regulations Air will flow through the permanent inlets on the outside walls of the stove Position the stove far from inflammable objects such as wooden furniture curtains and sofas If the sto...

Page 9: ...your children s safety For your own safety and comfort please make sure that the room has a suitable air scoop UNI10683 For the good functioning of the stove leave adequate clearance and air for the...

Page 10: ...dotto fumario non sia inferiore al 3 di inclinazione nei tratti orizzontali La lunghezza complessiva non deve superare i 2 mt ed il tratto verticale da un raccordo a T ad un altro cambio di direzione...

Page 11: ...nk during packaging Make sure there is nothing left inside the tank 9 1 FUEL CHARGE When loading the fuel make sure the bag containing the pellets doesn t touch the stove The fuel has to be loaded in...

Page 12: ...ing residues Reposition the flame retardant plate and the ash pan Reposition the ash pan making sure that the bigger hole on its right side its with the ignition resistance pipe Figure 18 18 Close the...

Page 13: ...of the first off area The switching on and off phase is signalled by a flashing green LED flashing very fast 5 times per second You can fill the auger in if you switch the stove on for the absolute fi...

Page 14: ...he stove is on at level 2 power Green 3 Flashes The stove is on at level 3 power Green 4 Flashes The stove is on at level 4 power Green 5 Flashes The stove is on at level 5 power Green The led stops f...

Page 15: ...tches on the alarm Alarm Faulty fume probe If the temperature detected by the environment probe is less than 20 C or more than 300 C Alarm Black out Failed mains power source Encoder alarm No signal f...

Page 16: ...hanged according to the values Ex 1 2 3 4 5 A A Automatic Combustion After 3 seconds the new value is memorised and the display shows as normal Work Thermostat Setting D2 D1 P2 P1 OFF D3 P4 Click P3 C...

Page 17: ...a submenu push the button P2 To modify the blinking value push the button P3 to increase or P4 to decrease To exit push the button P1 Chrono It allows to programme and enable the ignitions extinguish...

Page 18: ...socket Wear safety devices e g anti perforation gloves when carrying out maintenance operations Carry out maintenance when the stove is shut down and completely cooled off 15 OPERATIONS TO BE CARRIED...

Page 19: ...area subject to anomalous environmental conditions or if damages occur because of atmospheric agents or because of climate chemical or electrochemical factors The warranty is not valid if bad functio...

Page 20: ...Operating installation and maintenance manual BRUSCHETTA BRU70D BRU70M 20...

Page 21: ...from the purchase date N B The form is either registered or sent back to the purchaser The latter needs to save the warranty certificate and the fiscal receipt showing the purchase date I hereby autho...

Page 22: ...erating installation and maintenance manual BRUSCHETTA BRU70D BRU70M 22 Via Papa Giovanni XXIII 61045 PERGOLA PU ITALY T 39 0721 736733 F 39 0721 739315 www piquadrocalore com service piquadrocalore c...

Reviews: