41
YPM-2306ZF
5) Focus and Tracking Automatic Gain Control
This function is used for implementing automatic con-
trol of the focus and tracking loop gain.
The following is the adjustment procedure :
(1) Inject disturbance to the servo loop.
(2) Extract the error signal (FE and TE) generated at
when the disturbance is applied to obtain the sig-
nals G1 and G2 via the B.P.F.
(3) The microcomputer reads the G1 and G2 signals via
the LSI.
(4) Based on the necessary correction calculated by the
microcomputer, the LSI performs the loop gain
adjustment.
Above adjustments are repeated several times to
ensure higher adjustment accuracy.
6) Automatic RF Level Adjustment (RFAGC)
This adjustment is used for implementing intended sig-
nal transmission successfully by adjusting unevenness
of the RF signal (RFO) levels, that results from disc and
machine relevant factors, to a target value. The adjust-
ment is actually done by varying gain of the amplifier
provided between the RFI and RFO.
The following is the adjustment procedure :
(1) Using the command, the microcomputer reads the
output from the RF level detection circuit on the
servo LSI.
(2) Based on the read value, the microcomputer calcu-
lates an amplifier gain that will produce the target
RFO level.
(3) The microcomputer sends the corresponding com-
mand to the servo LSI so that the above gain value
may be set.
This adjustment takes place at the following timing :
• When the focus close alone is completed during the
setup process.
• Just before the setup is completed (just before the
play takes place).
• After the off-focus has been corrected during the play.
7) Adjustment of Pre-Amp Stage Gain
It is used for adjusting the entire RFAMP (FE, TE and RF
amplifiers) to
+
6dB or
+
12dB depending on given gain
level when reflected light from the disc is significantly
below the required level due to stained lens. This phe-
nomena can be noticed when playing back the CD-RW.
The following is the adjustment procedure :
When reflected light from disc is judged to be signifi-
cantly below the required level during the setup, set the
entire RFAMP to
+
6dB or
+
12dB. In this case, if the gain
is modified, the setup have to be repeated from the first
step.
Through the adjustment, if you judged the play
becomes available by setting the entire RFAMP to
+
6dB,
+
6dB should be selected for the setup next time on.
See the figure below :
,
y
,
y
,
y
,
y
,
y
,,
yy
Play at +6dB increases due to stained lens or other reasons
(the typical gain is employed for the initial setup)
Time
Gain of entire RFAMP
+
12dB
+
6dB
TYP
Play the CD-RW with the gain being set to
+
12dB
Play is started with
+
6dB
judging the lens is stained
Fig.19 : CONCEPTUAL DIAGRAM OF PRE-AMP GAIN ADJUSTMENT
Summary of Contents for YPM-2106ZF
Page 3: ...YPM 2306ZF 2 EXPLODED VIEWS AND PARTS LIST 2 1 CD MECHANISM MODULE 3 ...
Page 11: ...11 YPM 2306ZF ...
Page 13: ...13 YPM 2306ZF 1 2 3 4 1 2 3 4 D C B A SIDE B A CLAMP CONTROL UNIT S8 A ...
Page 19: ...19 YPM 2306ZF Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...