85
XR-A550MD
Ambient temperature
Correction value
–0.9 °C to +2.7 °C
–06 H
+2.7 °C to +6.3 °C
–05 H
+6.3 °C to +10.0 °C
–04 H
+10.0 °C to +14.5 °C
–03 H
+14.5 °C to +18.2 °C
–02 H
+18.2 °C to +22.3 °C
–01 H
+22.3 °C to +26.3 °C
±0 H
+26.3 °C to +30.3 °C
+01 H
+30.3 °C to +34.6 °C
+02 H
+34.6 °C to +39.0 °C
+03 H
+39.0 °C to +42.8 °C
+04 H
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
[ tsm
????
e
??
]
Step 2
Press the MENU button 7 times. EEPROM Setting Menu
[ EEPROM_ SET]
Step 3
Press the
`
button.
Focus Setting Menu
[ _ _ Focus_ _ _ ]
Step 4
Press the MENU button 4 times. TEMP Setting Menu
[ _ _ _ Temp_ _ _ ]
Step 5
Press the
`
button.
TEMP standard value setting
[ TEMP_
??
_
♦♦
]
(e) TEMP Setting
♦♦
: Set value,
??
: Measured value
If the
¡
button is pressed while a setting item is being displayed, the set value will increase and the new set value will be set in LSI.
If the
1
button is pressed while a setting item is being displayed, the set value will increase and the new set value will be set in LSI.
If the
¡
/
1
buttons are pressed and held down, data will change continuously in 100ms cycles.
Step No.
Setting Method
Remarks
Display
Step 1
EJECT status (or No Mechanism status)
[ _ _ EJECT_ _ _ ]
Step 2
Press the ENTER button.
TEMP standard value setting
[ TEMP_
??
_
♦♦
]
EEPROM recording value = microcomputer measured value + correction value
* EEPROM recording value
Predicted value when measured with microcomputer when temperature is +25 °C.
* Microcomputer measured value
Predicted value when measured with microcomputer at a certain temperature.
* Correction value
Correction value for converting to +25 °C measured value (see Table at left).
Temperature Code Confirmation
After AUTO Adjustment has been completed, the temperature code will be read. If it is within
the ranges below, it is OK.
Measured Temperature Values
Correction Table
Ambient temperature
Temperature Code
–18.2 °C to +30.3 °C
06
+6.3 °C to +18.2 °C
07
Remarks
Display
[ tsm
????
e
??
]
Press the MENU button 7 times. EEPROM Setting Menu
[ EEPROM_ SET]
Focus Setting Menu
[ _ _ Focus_ _ _ ]
Press the MENU button 5 times. CONTROL Setting Menu
[ _ Control_ _ ]
CONTROL 1 Setting
[ CONTRL1_
♦♦
]
CONTROL 2 Setting
[ CONTRL2_
♦♦
]
Step 7
Press the MENU button.
Spin kick level setting during Move
[ SPKLEVm_
♦♦
]
Step 8
Press the MENU button.
Readjustment interval (minutes) setting
[ ADJTTM_
♦♦
]
Step 9
Press the MENU button.
Equalizer coefficient A, D (high reflectance) setting
[ HDEQAD_
♦♦
]
Step 10
Press the MENU button.
Equalizer coefficient A, D (low reflectance) setting
[ LDEQAD_
♦♦
]
Step 11
Press the MENU button.
Equalizer coefficient A, D (low reflectance groove) setting
[ GDEQAD_
♦♦
]
Step 12
Press the MENU button.
Equalizer coefficient B, C (high reflectance) setting
[ HDEQBC_
♦♦
]
Step 13
Press the MENU button.
Equalizer coefficient B, C (low reflectance pit) setting
[ LDEQBC_
♦♦
]