77
XR-A550MD
TEST MODE : CANCEL
IC1402
Short
Fig.2 PWB-A (MD MAIN ASSY) Short Point
2
8
SIDE B
PWB-A
(MD MAIN ASSY)
E
When this is displayed, it is called "Test Mode Stop status."
In "Test Mode Stop status" and "EJECT status":
Operation will switch to the mechanism forced EJECT direction while
¡
button is pressed.
Operation will switch to the mechanism forced LOAD direction while
1
button is pressed.
In each Menu status:
The mechanism slide outer track feed will operate while the S.M. JOG key is turned clockwise.
The mechanism slide inner track feed will operate while the S.M. JOG key is turned counterclockwise.
To move according to the adjusted value set in Test Mode, Press the PRESET key in Test Mode Stop status. The adjusted value will be written
to EEPROM and the AUTO Adjustment Disabled Mode will be engaged.
Notes)
Canceling the AUTO Adjustment Disabled Mode will stop the power supply. (If a receiver is connected, disconnect the receiver power
cord.)
When a setting is changed in Test Mode and the unit is moved according to that setting, the mechanism may not operate if the set value
is faulty. When changing a set value, therefore, make a note of the original value.
In Test Mode the companion may be not only the SX-R9 but also the power jig. When the TEST2 terminal has been shorted without a bus
being received even once after RESET, the bus data will be ignored and POWER ON status determined, and the unit will operate
independently.
When the TEST2 terminal is shorted again under these conditions, the normal operation will be restored.
[ t s m
????
e
??
]
EEPROM protect data version (from 01)
Microcomputer ROM version (from 01)
Model code
Microcomputer Version Display (1 sec)
(1 second when EJECT is completed.)
Turn the Power OFF.
MD Mechanism Test Mode
When the MD mechanism pickup and PWB-A (MD MAIN Assy)
are newly assembled enter the MD mechanism Test Mode and
execute AUTO Preliminary Adjustment and AUTO Adjustment
according to the following procedure.
(1) Short-circuit pin 8 (PROTECT) and pin 2 (Vcc) of IC1402
(2) Enter the MD mechanism Test Mode and execute AUTO
Preliminary Adjustment and AUTO Adjustment.
(3) Press the PRESET key and quit Test Mode. (EEPROM will
(4) Cancel the shorting of pin 8 and pin 2 of IC1402.
Carry out the above procedure and turn the power OFF.