5. DIAGNOSIS
5.1 TROUBLESHOOTING
[1] Power failure
Symptom:
S
W
ITCHI
N
G PO
W
ER is fault.
Diagnostic procedure:
1. Check if S
W
ITCHI
N
G PO
W
ER C
N
1: AC 100
V
to AC 240
V
is normal.
2. Check S
W
ITCHI
N
G PO
W
ER C
N
3:
V
1
→
+7
V
,
V
2
→
ST5
V
,
V
3
→
+15
V
,
V
4
→
-15
V
,
V
5
→
6
V
.
3. Check waveform for S
W
ITCHI
N
G PO
W
ER, confirm it is correct.
S
W
ITCHI
N
G PO
W
ER C2
8
positive to ground is +7
V
figure (
W
aveform ).
S
W
ITCHI
N
G PO
W
ER C47 positive to ground is ST5
V
figure (
W
aveform ).
S
W
ITCHI
N
G PO
W
ER C31 positive to ground is +15
V
figure (
W
aveform ).
S
W
ITCHI
N
G PO
W
ER C24 negative to ground is -15
V
figure (
W
aveform ).
S
W
ITCHI
N
G PO
W
ER C21 positive to ground is +6
V
figure (
W
aveform ).
4. If
W
aveform is abnormal, you could change it.
[2] VFD dose not light
Symptom:
V
FD module is fault, it is no light-emitting.
Diagnostic procedure:
1. Check waveform for
V
FD module, you confirm it is correct.
Check CD Assy C112 positive to ground is +Ef figure (
W
aveform ).
Check CD Assy C112 negative to ground is -Ef figure (
W
aveform ).
Check CD Assy C103 positive to ground is
V
H figure (
W
aveform ).
2. If
W
aveform is abnormal, you could change it.
[3] LED dose not light
Symptom:
LED part is fault, it is no light-emitting.
Diagnostic procedure:
1. Check waveform for LED, you confirm it is correct.
2. It is tested at CD Assy Q102 to Q105 pin C (CH1).
It is tested at CD Assy Q106 to Q112 pin C (CH2).
W
aveform for LED O
N
is figure (
W
aveform ).
W
aveform for LED OFF is figure (
W
aveform ).
3. If
W
aveform is abnormal, you could change it.
[4-1] No key functions
Symptom:
N
o key function.
Diagnostic procedure:
1. Check waveform for KEY, you confirm it is correct.
W
aveform for KEY OFF is figure (
W
aveform )(CH1
→
KEY pin 1/CH2
→
KEY pin 2).
W
aveform for KEY O
N
is figure (
W
aveform )(CH1
→
KEY pin 1/CH2
→
KEY pin 2).
2. If
W
aveform is abnormal, you could change it.
[4-2] Rotary selector not controllable
Symptom:
Rotary selector of encoder switch is fault.
Diagnostic procedure:
1. Check waveform for rotary encoder, you confirm it is correct.
W
aveform for rotary encoder is figure (
W
aveform )(CH1
→
encoder pin 1/CH2
→
encoder pin 3).
2. If
W
aveform is abnormal, you could change it.
[4-3] Slider volume not controllable
Symptom:
Crossfader and channel-fader
V
R is fault.
Diagnostic procedure:
1. Check waveform for
V
R, you confirm it is correct.
C
8
02 (CROSSFADER), C
8
07 (CH1 FADER), C
8
06 (CH2 FADER) that positive to ground is
V
R out.
W
aveform for min
V
R out is figure (
W
aveform ).
W
aveform for max
V
R out is figure (
W
aveform ).
2. If
W
aveform is abnormal, you could change it.
1-1
1-2
1-3
1-4
1-5
2-1
2-2
2-3
3-1
4-1
4-2
4-3
4-4
4-5
3-2