VSX-C301-S
80
1
2
3
4
1
2
3
4
C
D
F
A
B
E
7. GENERAL INFORMATION
7.1 DIAGNOSIS
7.1.1 Test Mode
• How to Enter the Test Mode
With the attached Remote Control Unit
1. Test mode ON
"MENU" key
When Test mode is entered, "TEST" is indicated for 5 seconds.
Settings other than those described below return to the factory-
preset values.
• Function: TV/SAT
• Signal select: AUTO
• Settings for the speakers: All large, SW ON
• No automatic speaker detection
• PRO LOGIC2 EMU mode
• The tuner is preset for Test mode.
• SOUND MODE: OFF
The Protection process (Key Mask for 1 min.) is canceled.
2. Test mode OFF
"9" key
When the code is received, Test mode is terminated, and all
settings return to the factory-preset values.
With "RECEIVER " key, Test mode is also terminated, and all
settings return to the factory-preset values.
3.FL/LED check
"0" key
Each time the remote control code is received, the indications on
the FL and LED change cyclically, as shown below.
All segments on the FL and LED light.
→
All segments on the
FL and LED go off.
→
"ABCDEFGH" are displayed on the FL,
and 1, 3, 5, 7 are displayed on the LED.
→
"IJKLMNOP" are
displayed on the FL, and 2, 4, 6, 8 are displayed on the LED.
→
Usual display
→
. . . .
When the code is first received, all segments light.
4. SP relay change
"1" key
Each time the remote control code is received, the SP relay is
turned off then back on. When the code is first received, the SP
relay is turned off.
5. DOLBY Pro Logic2 mode
"2" key
When the code is received, settings other than those described
below return to the factory-preset values.
• Function: DVD/LD
• Signal select: AUTO
• Distance of Rear speaker: 5 feet
• STANDARD PRO LOGIC2 EMU mode
• Speaker setting: LLLLY
7. MASTER VOL CHANGE
"4" key
Each time the remote control code is received, the master volume
is changed as follows: minus infinity
→
0 dB
→
. . . .
Each trim becomes 0 dB.
When the code is first received, the master volume becomes
minus infinity (MUTE.)
8. 9K/10K CHANGE
"5" key
For the FL (international) model only, when the code is received,
9K and 10K can be switched.
When the code is first received, 10K is selected.
9. Automatic detection of speakers
"7" key
When the remote control code is received, detection of speakers
starts automatically. The results (C_S_W_) will be displayed for
5 seconds. The symbol "
Ο
" means the speaker is connected, and
"
×
" means the speaker is not connected.
C301: C
×
S
×
W
×
10. Analog input check
"8" key
When the remote control code is received, Forced Analog Input,
and 2-channel STEREO mode are set for all functions.
• Settings for the speakers: All large, SW ON
• When Analog Input Check mode is entered, "SIG:ANA" is
displayed for 5 seconds.
11. Digital input check
"3" key
When the remote control code is received, Forced Digital Input,
and 2-channel STEREO mode are set for all functions.
• Settings for the speakers: All large, SW ON
• When Digital Input Check mode is entered, "SIG:DIG" is
displayed for 5 seconds.
12. Version display
"1" key
When the code is received, the versions of the main
microcomputer, display microcomputer, and DSP are displayed.
After the versions of microcomputers are displayed for 5 seconds,
DSP version is displayed for 5 seconds.
Examples:
"M011F001": Main microcomputer: Ver. 011, display
microcomputer: Ver. 001
"PPP. 031": DSP: Ver. 031
Note : Test mode of No. 1-12 is Preset ID 150.
Test mode of No. 13, 14 is Preset ID 156.
Summary of Contents for VSX-C301-S
Page 17: ...VSX C301 S 17 5 6 7 8 5 6 7 8 C D F A B E ...
Page 23: ...VSX C301 S 23 5 6 7 8 5 6 7 8 C D F A B E ...
Page 35: ...VSX C301 S 35 5 6 7 8 5 6 7 8 C D F A B E J6001 O CN4201 L D 5 5 ...
Page 36: ...VSX C301 S 36 1 2 3 4 1 2 3 4 C D F A B E 3 11 DSP ASSY 1 2 F 1 2 CN1264 D 2 5 ...
Page 38: ...VSX C301 S 38 1 2 3 4 1 2 3 4 C D F A B E 3 12 DSP ASSY 2 2 D1 5 CN9005 F 2 2 ...