IEEE 1394 Error Indications
No.
Message
Error Code
Cause and Actions to be taken
Remarks
1
WRITING
CONFIG
E7
The Config ROM data are being written to flash memory.
Do NOT turn off the power while this message is displayed.
While this message is displayed, the Standby button on the
main unit is disabled.
This message is displayed when a unit whose host board was
replaced with a new one is turned on for the first time.
2
MODEL ID
ERROR
CO
The MODEL ID stored in flash memory on the host board and
that stored in the main unit do not match.
Download the GUID again.
This error is generated when a host board for the wrong
destination is mounted in the unit, and it will only be generated
during servicing. The message will remain displayed until the
error is corrected.
3
CONFIG
ERROR
C1
The Config ROM data are erroneous.
Download the GUID again.
This message is displayed when the power is turned off while
the Config ROM data are being written. As this is generated
while the unit is operated online, this error will only be
generated during servicing. The message will remain displayed
until the error is corrected.
Note:
If downloading of the GUID cannot be performed for corrective measures for messages 1 and 2, replace the host board with a new